The design and application of digital quick standby protection for transformer

Jian Sun

Open publisher page 0 citations

Abstract

Usually there are no bus bar protection in 10kV bus bar of 110kV substation. Therefore, when short circuit fault in 10kV bus bar occurs, to remove the fault depends on standby protection at 10kV side of transformer. The set time of the protection has to be cooperated with that of outgoing_line overcurrent protection, then time_delay is over 2 seconds.So the time of removing fault is long, the equipment is badly damaged. Considering the facts of Yun Nan Province Diandong electric power network, the configuration and design of main transformer for the substation are discussed. A new operation mode and complete protection configuration scheme are brought forward.

About this research paper

What this paper is about

Usually there are no bus bar protection in 10kV bus bar of 110kV substation. Therefore, when short circuit fault in 10kV bus bar occurs, to remove the fault depends on standby protection at 10kV side of transformer. The set time of the protection has to be cooperated with that of outgoing_line overcurrent protection, then time_delay is over 2 seconds.So the time of removing fault is long, the equipment is badly damaged. Considering the facts of Yun Nan Province Diandong electric power network, the configuration and design of main transformer for the substation are discussed. A new operation mode and complete protection configuration scheme are brought forward.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Usually there are no bus bar protection in 10kV bus bar of 110kV substation. Therefore, when short circuit fault in 10kV bus bar occurs, to remove the fault depends on standby protection at 10kV side of transformer. The set time of the protection has to be cooperated with that of outgoing_line overcurrent protection, then time_delay is over 2 seconds.So the time of removing fault is long, the equipment is badly damaged. Considering the facts of Yun Nan Province Diandong electric power network, the configuration and design of main transformer for the substation are discussed. A new operation mode and complete protection configuration scheme are brought forward.

Key concepts: Busbar, Overcurrent, Standby power, Transformer, Engineering, Power-system protection, Electrical engineering, Circuit breaker

Related papers

Back to paper searchBrowse research topicsOriginal source
The design and application of digital quick standby protection for transformer — Research Paper | ScholarLens