Objective To evaluate the capability for detecting of tumor cells in ascitic and pleural fluids by Sysmex XE-5000 hematology analyzer.Methods 91 EDTA-K2 ascitic and pleural fluids samples were counted by Sysmex XE-5000 hematology analyzer.Highly fluorescent body fluid cells percent(HF-BF%) and scatter diagram were observed in the samples to evaluate the capability of detection of tumor cells.SPSS11.5 and Excel were used for statistical analysis.Results The samples with tumor cells showed increased Highly fluorescent body fluid cells percent(HF-BF%) compared with benign samples.Bright band composed by dense cells whose distribution was located at the zone with high side fluorescence lights(SFL) and side scattered lights(SSC) in scatter diagram provided information about the possible presence of tumor cells.Conclusion Highly fluorescent body fluid cells percent(HF-BF%) and distinguishing feature of scatter diagram can provide screening information about the presence of tumor cells.This suggests that such increase should lead to a manual differential review and an extensive examination of slides to check the presence of abnormal cells.

About this research paper

What this paper is about

Objective To evaluate the capability for detecting of tumor cells in ascitic and pleural fluids by Sysmex XE-5000 hematology analyzer.Methods 91 EDTA-K2 ascitic and pleural fluids samples were counted by Sysmex XE-5000 hematology analyzer.Highly fluorescent body fluid cells percent(HF-BF%) and scatter diagram were observed in the samples to evaluate the capability of detection of tumor cells.SPSS11.5 and Excel were used for statistical analysis.Results The samples with tumor cells showed increased Highly fluorescent body fluid cells percent(HF-BF%) compared with benign samples.Bright band composed by dense cells whose distribution was located at the zone with high side fluorescence lights(SFL) and side scattered lights(SSC) in scatter diagram provided information about the possible presence of tumor cells.Conclusion Highly fluorescent body fluid cells percent(HF-BF%) and distinguishing feature of scatter diagram can provide screening information about the presence of tumor cells.This suggests that such increase should lead to a manual differential review and an extensive examination of slides to check the presence of abnormal cells.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To evaluate the capability for detecting of tumor cells in ascitic and pleural fluids by Sysmex XE-5000 hematology analyzer.Methods 91 EDTA-K2 ascitic and pleural fluids samples were counted by Sysmex XE-5000 hematology analyzer.Highly fluorescent body fluid cells percent(HF-BF%) and scatter diagram were observed in the samples to evaluate the capability of detection of tumor cells.SPSS11.5 and Excel were used for statistical analysis.Results The samples with tumor cells showed increased Highly fluorescent body fluid cells percent(HF-BF%) compared with benign samples.Bright band composed by dense cells whose distribution was located at the zone with high side fluorescence lights(SFL) and side scattered lights(SSC) in scatter diagram provided information about the possible presence of tumor cells.Conclusion Highly fluorescent body fluid cells percent(HF-BF%) and distinguishing feature of scatter diagram can provide screening information about the presence of tumor cells.This suggests that such increase should lead to a manual differential review and an extensive examination of slides to check the presence of abnormal cells.

Key concepts: Hematology analyzer, Body fluid, Pleural fluid, Pathology, Pleural effusion, Ascitic fluid, Fluorescence, Cell counting

Related papers

Back to paper searchBrowse research topicsOriginal source
Evaluation of the new body fluid mode on the Sysmex XE-5000 for detecting of tumor cells in ascitic and pleural fluids — Research Paper | ScholarLens