The scanning protocol of 256-slice spiral CT for bronchial artery CT angiography

Xie Ru-kui

Open publisher page 0 citations

Abstract

Objective:Comparison of different scanning and injection protocols for bronchial artery CT angiography(CTA).Methods:Eighty cases scheduled for bronchial artery CTA were randomly assigned into four groups according to the injection protocol.Cases in group 1 to group 3 adopted the injection rate of 4,5 and 6 ml/s respectively,and used automatic threshold preset at 300 HU to trigger the initiation of the scan,with total contrast dose of 1.5 ml/kg body weight.Cases in the group 4 adopted an injection rate of 6 ml/s,triggering threshold of 120 HU,and 1.0 ml/kg body weight of contrast.High density contrast(350 mgI/ml)was used in all cases.The CT values of pulmonary artery,superior vena cava,aortic artery and bronchial artery before and after enhanced scanning were measured in the 4 groups.Numbers of cases with excellent image quality of bronchial artery display were also evaluated.Results:The CT values of pulmonary artery and superior vena cava among four groups hadn't significant difference(P 0.05).The CT values of aortic artery in group 4 were higher than other three groups significantly(P 0.05).The CT values of bronchial artery in group 4 were higher than group 1 and group 2 significantly(P 0.05).The excellent rate of bronchial artery CTA for group one to group four were: 50%,55%,65% and 80%,respectively.Conclusion:This research showed that the injection rate of 6 ml/s,triggering threshold of 120 HU,1.0 ml/kg body weight of high density contrast dose provide higher contrast,and it's on optimal protocol for bronchial artery CTA.

About this research paper

What this paper is about

Objective:Comparison of different scanning and injection protocols for bronchial artery CT angiography(CTA).Methods:Eighty cases scheduled for bronchial artery CTA were randomly assigned into four groups according to the injection protocol.Cases in group 1 to group 3 adopted the injection rate of 4,5 and 6 ml/s respectively,and used automatic threshold preset at 300 HU to trigger the initiation of the scan,with total contrast dose of 1.5 ml/kg body weight.Cases in the group 4 adopted an injection rate of 6 ml/s,triggering threshold of 120 HU,and 1.0 ml/kg body weight of contrast.High density contrast(350 mgI/ml)was used in all cases.The CT values of pulmonary artery,superior vena cava,aortic artery and bronchial artery before and after enhanced scanning were measured in the 4 groups.Numbers of cases with excellent image quality of bronchial artery display were also evaluated.Results:The CT values of pulmonary artery and superior vena cava among four groups hadn't significant difference(P 0.05).The CT values of aortic artery in group 4 were higher than other three groups significantly(P 0.05).The CT values of bronchial artery in group 4 were higher than group 1 and group 2 significantly(P 0.05).The excellent rate of bronchial artery CTA for group one to group four were: 50%,55%,65% and 80%,respectively.Conclusion:This research showed that the injection rate of 6 ml/s,triggering threshold of 120 HU,1.0 ml/kg body weight of high density contrast dose provide higher contrast,and it's on optimal protocol for bronchial artery CTA.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:Comparison of different scanning and injection protocols for bronchial artery CT angiography(CTA).Methods:Eighty cases scheduled for bronchial artery CTA were randomly assigned into four groups according to the injection protocol.Cases in group 1 to group 3 adopted the injection rate of 4,5 and 6 ml/s respectively,and used automatic threshold preset at 300 HU to trigger the initiation of the scan,with total contrast dose of 1.5 ml/kg body weight.Cases in the group 4 adopted an injection rate of 6 ml/s,triggering threshold of 120 HU,and 1.0 ml/kg body weight of contrast.High density contrast(350 mgI/ml)was used in all cases.The CT values of pulmonary artery,superior vena cava,aortic artery and bronchial artery before and after enhanced scanning were measured in the 4 groups.Numbers of cases with excellent image quality of bronchial artery display were also evaluated.Results:The CT values of pulmonary artery and superior vena cava among four groups hadn't significant difference(P 0.05).The CT values of aortic artery in group 4 were higher than other three groups significantly(P 0.05).The CT values of bronchial artery in group 4 were higher than group 1 and group 2 significantly(P 0.05).The excellent rate of bronchial artery CTA for group one to group four were: 50%,55%,65% and 80%,respectively.Conclusion:This research showed that the injection rate of 6 ml/s,triggering threshold of 120 HU,1.0 ml/kg body weight of high density contrast dose provide higher contrast,and it's on optimal protocol for bronchial artery CTA.

Key concepts: Medicine, Bronchial artery, Artery, Pulmonary artery, Superior vena cava, Nuclear medicine, Angiography, Radiology

Related papers

Back to paper searchBrowse research topicsOriginal source
The scanning protocol of 256-slice spiral CT for bronchial artery CT angiography — Research Paper | ScholarLens