2006•Gao dianya jishuRequires access

Study on Electromagnetic Environment for 1000kV AC Transmission Line

Yao Lu

Open publisher page 11 citations

Abstract

“Jing Cheng-Nan Yang-Jing Zhou 1000kV AC pilot project” and “Huai Nan-Wu Hu-Shang Hai 1000kV AC project” of SGCC are the major projects of UHV grid on the stocks in our country. Based on summarizing the abroad and domestic research results of electromagnetic environment for UHV power transmission line, and combined with the calculation and analysis of electromagnetic environment parameters for major tower and conductor type of preliminary design of UHV power transmission line in China, the suggestions for parameters indexes control of electromagnetic environment for 1000kV power transmission line such as power frequency electric field, power frequency magnetic field, radio interference and audible noise were put forward. The limit of the electric field strength is determined as follows: 1) The limit for the area that people can be easily come to and the road that overhead line crossed is 7 kV/m; 2) The limit for the farm field that overhead line crossed is 10 kV/m; 3) The limit for the area near the domestic structure is 4 kV/m; 4) The designed value for the radio interference is 55-58 dB; 5) The designed value for the audible noise is 55 dB.

About this research paper

What this paper is about

“Jing Cheng-Nan Yang-Jing Zhou 1000kV AC pilot project” and “Huai Nan-Wu Hu-Shang Hai 1000kV AC project” of SGCC are the major projects of UHV grid on the stocks in our country. Based on summarizing the abroad and domestic research results of electromagnetic environment for UHV power transmission line, and combined with the calculation and analysis of electromagnetic environment parameters for major tower and conductor type of preliminary design of UHV power transmission line in China, the suggestions for parameters indexes control of electromagnetic environment for 1000kV power transmission line such as power frequency electric field, power frequency magnetic field, radio interference and audible noise were put forward. The limit of the electric field strength is determined as follows: 1) The limit for the area that people can be easily come to and the road that overhead line crossed is 7 kV/m; 2) The limit for the farm field that overhead line crossed is 10 kV/m; 3) The limit for the area near the domestic structure is 4 kV/m; 4) The designed value for the radio interference is 55-58 dB; 5) The designed value for the audible noise is 55 dB.

Why it matters

OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

“Jing Cheng-Nan Yang-Jing Zhou 1000kV AC pilot project” and “Huai Nan-Wu Hu-Shang Hai 1000kV AC project” of SGCC are the major projects of UHV grid on the stocks in our country. Based on summarizing the abroad and domestic research results of electromagnetic environment for UHV power transmission line, and combined with the calculation and analysis of electromagnetic environment parameters for major tower and conductor type of preliminary design of UHV power transmission line in China, the suggestions for parameters indexes control of electromagnetic environment for 1000kV power transmission line such as power frequency electric field, power frequency magnetic field, radio interference and audible noise were put forward. The limit of the electric field strength is determined as follows: 1) The limit for the area that people can be easily come to and the road that overhead line crossed is 7 kV/m; 2) The limit for the farm field that overhead line crossed is 10 kV/m; 3) The limit for the area near the domestic structure is 4 kV/m; 4) The designed value for the radio interference is 55-58 dB; 5) The designed value for the audible noise is 55 dB.

Key concepts: Electromagnetic environment, Overhead line, Electrical engineering, Electric power transmission, Transmission line, Electromagnetic interference, Limit (mathematics), Noise (video)

Related papers

Back to paper searchBrowse research topicsOriginal source
Study on Electromagnetic Environment for 1000kV AC Transmission Line — Research Paper | ScholarLens