Based on summarizing the domestic and international research results of electromagnetic environment for UHV power transmission line, and combined with the calculation and analysis of electromagnetic environment parameters for major tower and conductor type of preliminary design of UHV power transmission line in China, the suggestions for parameter indexes control of electromagnetic environment for 1 000 kV power transmission and transformation project such as power frequency electric field, power frequency magnetic field, radio influence and audible noise were put forward. The suggestions in the area that public is close to easily show that the limited value of electric field intensity for the line of crossing highway is 7 kV/m, the limited value of electric field intensity for the line of crossing farm is 10 kV/m, the design value of anti-radio-influence is 55~58 dB, the design standard for audible noise control is in 55 dB etc..
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Based on summarizing the domestic and international research results of electromagnetic environment for UHV power transmission line, and combined with the calculation and analysis of electromagnetic environment parameters for major tower and conductor type of preliminary design of UHV power transmission line in China, the suggestions for parameter indexes control of electromagnetic environment for 1 000 kV power transmission and transformation project such as power frequency electric field, power frequency magnetic field, radio influence and audible noise were put forward. The suggestions in the area that public is close to easily show that the limited value of electric field intensity for the line of crossing highway is 7 kV/m, the limited value of electric field intensity for the line of crossing farm is 10 kV/m, the design value of anti-radio-influence is 55~58 dB, the design standard for audible noise control is in 55 dB etc..
Key concepts: Electromagnetic environment, Electrical engineering, Engineering, Electric power transmission, Transmission line, Noise (video), Power transmission, Power (physics)