2005•Electrical EquipmentRequires access

Study on Electromagnetic Environment for 1000 kV AC Power Transmission Line

Wu Xiong

Open publisher page 0 citations

Abstract

Based on summarizing the domestic and international research results of electromagnetic environment for UHV power transmission line, and combined with the calculation and analysis of electromagnetic environment parameters for major tower and conductor type of preliminary design of UHV power transmission line in China, the suggestions for parameter indexes control of electromagnetic environment for 1 000 kV power transmission and transformation project such as power frequency electric field, power frequency magnetic field, radio influence and audible noise were put forward. The suggestions in the area that public is close to easily show that the limited value of electric field intensity for the line of crossing highway is 7 kV/m, the limited value of electric field intensity for the line of crossing farm is 10 kV/m, the design value of anti-radio-influence is 55~58 dB, the design standard for audible noise control is in 55 dB etc..

About this research paper

What this paper is about

Based on summarizing the domestic and international research results of electromagnetic environment for UHV power transmission line, and combined with the calculation and analysis of electromagnetic environment parameters for major tower and conductor type of preliminary design of UHV power transmission line in China, the suggestions for parameter indexes control of electromagnetic environment for 1 000 kV power transmission and transformation project such as power frequency electric field, power frequency magnetic field, radio influence and audible noise were put forward. The suggestions in the area that public is close to easily show that the limited value of electric field intensity for the line of crossing highway is 7 kV/m, the limited value of electric field intensity for the line of crossing farm is 10 kV/m, the design value of anti-radio-influence is 55~58 dB, the design standard for audible noise control is in 55 dB etc..

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Based on summarizing the domestic and international research results of electromagnetic environment for UHV power transmission line, and combined with the calculation and analysis of electromagnetic environment parameters for major tower and conductor type of preliminary design of UHV power transmission line in China, the suggestions for parameter indexes control of electromagnetic environment for 1 000 kV power transmission and transformation project such as power frequency electric field, power frequency magnetic field, radio influence and audible noise were put forward. The suggestions in the area that public is close to easily show that the limited value of electric field intensity for the line of crossing highway is 7 kV/m, the limited value of electric field intensity for the line of crossing farm is 10 kV/m, the design value of anti-radio-influence is 55~58 dB, the design standard for audible noise control is in 55 dB etc..

Key concepts: Electromagnetic environment, Electrical engineering, Engineering, Electric power transmission, Transmission line, Noise (video), Power transmission, Power (physics)

Related papers

Back to paper searchBrowse research topicsOriginal source
Study on Electromagnetic Environment for 1000 kV AC Power Transmission Line — Research Paper | ScholarLens