2004•Metallurgical AnalysisRequires access

Determination of impurity elements in high purity copper cathode by ICP-AES

Hongwei Liu

Open publisher page 0 citations

Abstract

A new method for simultaneous determination of Pb,Fe,Bi,Sb,As,Sn,Ni,Zn,P,S,Ag,Se,Te,Si,Mn and Cr in high purity copper cathode by ICP-AES after separation of copper by sodium chloride-sodium diethyldthiocarbamate-n-propanol system in the presence of EDTA is discussed. The detection limit of the method is in the range of 0.003-0.028 μg/mL. The recovery for the elements is from 94.5% to 107.2%. RSD is less than 4.7%. This method is accurate,rapid and convenient.It is used for the determination of impurity elements in high purity copper cathode with satisfactory results.

About this research paper

What this paper is about

A new method for simultaneous determination of Pb,Fe,Bi,Sb,As,Sn,Ni,Zn,P,S,Ag,Se,Te,Si,Mn and Cr in high purity copper cathode by ICP-AES after separation of copper by sodium chloride-sodium diethyldthiocarbamate-n-propanol system in the presence of EDTA is discussed. The detection limit of the method is in the range of 0.003-0.028 μg/mL. The recovery for the elements is from 94.5% to 107.2%. RSD is less than 4.7%. This method is accurate,rapid and convenient.It is used for the determination of impurity elements in high purity copper cathode with satisfactory results.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new method for simultaneous determination of Pb,Fe,Bi,Sb,As,Sn,Ni,Zn,P,S,Ag,Se,Te,Si,Mn and Cr in high purity copper cathode by ICP-AES after separation of copper by sodium chloride-sodium diethyldthiocarbamate-n-propanol system in the presence of EDTA is discussed. The detection limit of the method is in the range of 0.003-0.028 μg/mL. The recovery for the elements is from 94.5% to 107.2%. RSD is less than 4.7%. This method is accurate,rapid and convenient.It is used for the determination of impurity elements in high purity copper cathode with satisfactory results.

Key concepts: Copper, Impurity, Detection limit, Cathode, Inductively coupled plasma atomic emission spectroscopy, Chemistry, Analytical Chemistry (journal), Sodium

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of impurity elements in high purity copper cathode by ICP-AES — Research Paper | ScholarLens