2005Journal of environmental healthRequires access

Determination of Trace Phenol in Waste Water by Inhibition Kinetic Spectrophotometry

Zheng Huai-l

Open publisher page 0 citations

Abstract

Objective To establish a method for determination of trace phenol in waste water. Methods It is reported that trace amounts of phenol can inhibit the decoloring reaction of methyl red by potassium bromate in dilute sulfuric acid medium. Results The linear range of this method was 0-17 μg/25 ml for phenol with detection limit of 6.53×10-9 g/ml, RSD was 0.96%-1.70%, recovery rate was 97.8%-102.0%. Conclusion The proposed method is simple, sensitive and can be applied to determine trace phenol in waste water with satisfactory results.

About this research paper

What this paper is about

Objective To establish a method for determination of trace phenol in waste water. Methods It is reported that trace amounts of phenol can inhibit the decoloring reaction of methyl red by potassium bromate in dilute sulfuric acid medium. Results The linear range of this method was 0-17 μg/25 ml for phenol with detection limit of 6.53×10-9 g/ml, RSD was 0.96%-1.70%, recovery rate was 97.8%-102.0%. Conclusion The proposed method is simple, sensitive and can be applied to determine trace phenol in waste water with satisfactory results.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To establish a method for determination of trace phenol in waste water. Methods It is reported that trace amounts of phenol can inhibit the decoloring reaction of methyl red by potassium bromate in dilute sulfuric acid medium. Results The linear range of this method was 0-17 μg/25 ml for phenol with detection limit of 6.53×10-9 g/ml, RSD was 0.96%-1.70%, recovery rate was 97.8%-102.0%. Conclusion The proposed method is simple, sensitive and can be applied to determine trace phenol in waste water with satisfactory results.

Key concepts: Potassium bromate, Phenol, Chemistry, Sulfuric acid, Spectrophotometry, Detection limit, Chromatography, Linear range

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Trace Phenol in Waste Water by Inhibition Kinetic Spectrophotometry — Research Paper | ScholarLens