2014•Rock and Mineral AnalysisRequires access

Determination of Trace Selenium in Biological Samples by Inductively Coupled Plasma-Mass Spectrometry with Microwave Digestion

Feng Yong-min

Open publisher page 2 citations

Abstract

Hydride Generation-Atomic Fluorescence Spectrometry(HG-AFS) with wet digestion is classical method to determine the trace element selenium in biological samples.The analytical requirements cannot be met by low resolution HG-AFS and wet digestion processing and carries the additional disadvantages of high quantities of reagent consumption,lengthy processing time and production of high background values.Accelerating digestion processing time and reducing the amount of reagent consumption have been considered as prerequisites for increasing detection limit and resolution of selenium.In this article,samples were analyzed by HG-AFS and Inductively Coupled Plasma-Mass Spectrometry(ICP-MS) after two different sample pretreatments of wet digestion and microwave digestion.The method of ICP-MS with microwave digestion was established through these contrast tests.The results indicate that microwave digestion can reduce digestion time,decrease reagent consumption and lower background in high-pressure sealed conditions.Detection limits of HG-AFS and ICP-MS are 0.03 μg / g and0.01 μg / g,respectively.In addition,according to the determination for national standard reference samples,relative standard deviations of HG-AFS and ICP-MS are less than 10% and 4%,respectively.Obviously,low detection limits and improved accuracy and precision can been acquired by direct analysis with ICP-MS.The established method is simple to operate and can been conducted for the rapid determination of trace selenium in various biological samples.

About this research paper

What this paper is about

Hydride Generation-Atomic Fluorescence Spectrometry(HG-AFS) with wet digestion is classical method to determine the trace element selenium in biological samples.The analytical requirements cannot be met by low resolution HG-AFS and wet digestion processing and carries the additional disadvantages of high quantities of reagent consumption,lengthy processing time and production of high background values.Accelerating digestion processing time and reducing the amount of reagent consumption have been considered as prerequisites for increasing detection limit and resolution of selenium.In this article,samples were analyzed by HG-AFS and Inductively Coupled Plasma-Mass Spectrometry(ICP-MS) after two different sample pretreatments of wet digestion and microwave digestion.The method of ICP-MS with microwave digestion was established through these contrast tests.The results indicate that microwave digestion can reduce digestion time,decrease reagent consumption and lower background in high-pressure sealed conditions.Detection limits of HG-AFS and ICP-MS are 0.03 μg / g and0.01 μg / g,respectively.In addition,according to the determination for national standard reference samples,relative standard deviations of HG-AFS and ICP-MS are less than 10% and 4%,respectively.Obviously,low detection limits and improved accuracy and precision can been acquired by direct analysis with ICP-MS.The established method is simple to operate and can been conducted for the rapid determination of trace selenium in various biological samples.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Hydride Generation-Atomic Fluorescence Spectrometry(HG-AFS) with wet digestion is classical method to determine the trace element selenium in biological samples.The analytical requirements cannot be met by low resolution HG-AFS and wet digestion processing and carries the additional disadvantages of high quantities of reagent consumption,lengthy processing time and production of high background values.Accelerating digestion processing time and reducing the amount of reagent consumption have been considered as prerequisites for increasing detection limit and resolution of selenium.In this article,samples were analyzed by HG-AFS and Inductively Coupled Plasma-Mass Spectrometry(ICP-MS) after two different sample pretreatments of wet digestion and microwave digestion.The method of ICP-MS with microwave digestion was established through these contrast tests.The results indicate that microwave digestion can reduce digestion time,decrease reagent consumption and lower background in high-pressure sealed conditions.Detection limits of HG-AFS and ICP-MS are 0.03 μg / g and0.01 μg / g,respectively.In addition,according to the determination for national standard reference samples,relative standard deviations of HG-AFS and ICP-MS are less than 10% and 4%,respectively.Obviously,low detection limits and improved accuracy and precision can been acquired by direct analysis with ICP-MS.The established method is simple to operate and can been conducted for the rapid determination of trace selenium in various biological samples.

Key concepts: Microwave digestion, Chemistry, Inductively coupled plasma mass spectrometry, Detection limit, Selenium, Digestion (alchemy), Reagent, Chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Trace Selenium in Biological Samples by Inductively Coupled Plasma-Mass Spectrometry with Microwave Digestion — Research Paper | ScholarLens