Evaluation of Time-resolved Fluoroimmunoassay of Serum AFP

Deng Guang-rong

Open publisher page 0 citations

Abstract

To evaluate the method ot time-resolved fluoroimmunoassay (TRFIA) for serum AFP, comparison of TRFIA with ELISA and RIA was carried out for the assay of AFP in the aspects of linear range, sensitivity, precision and recovery rate. The results showed that the linear range of AFP was 1-1000 U/mL, lower limit≤0. 1 U/mL,the CV within and between the assays was 2.3% and 5. 3%, respectively. The recovery rate was 97. 85%, being in high agreement with ELISA and RIA (the value of r was 0. 982 and 0. 991, respectively). The reference value of normal serum AFP was 0. 8 -10. 5 U/mL. Therefore, the sensitivity of TRFIA for serum AFP is high and covers a wide linear range. It is also highly accurate and is not related with radiolabeled or hazardous chemicals. TRFIA appears to be a useful biochemical ultrami-croanalysis technique worthy of further development.

About this research paper

What this paper is about

To evaluate the method ot time-resolved fluoroimmunoassay (TRFIA) for serum AFP, comparison of TRFIA with ELISA and RIA was carried out for the assay of AFP in the aspects of linear range, sensitivity, precision and recovery rate. The results showed that the linear range of AFP was 1-1000 U/mL, lower limit≤0. 1 U/mL,the CV within and between the assays was 2.3% and 5. 3%, respectively. The recovery rate was 97. 85%, being in high agreement with ELISA and RIA (the value of r was 0. 982 and 0. 991, respectively). The reference value of normal serum AFP was 0. 8 -10. 5 U/mL. Therefore, the sensitivity of TRFIA for serum AFP is high and covers a wide linear range. It is also highly accurate and is not related with radiolabeled or hazardous chemicals. TRFIA appears to be a useful biochemical ultrami-croanalysis technique worthy of further development.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

To evaluate the method ot time-resolved fluoroimmunoassay (TRFIA) for serum AFP, comparison of TRFIA with ELISA and RIA was carried out for the assay of AFP in the aspects of linear range, sensitivity, precision and recovery rate. The results showed that the linear range of AFP was 1-1000 U/mL, lower limit≤0. 1 U/mL,the CV within and between the assays was 2.3% and 5. 3%, respectively. The recovery rate was 97. 85%, being in high agreement with ELISA and RIA (the value of r was 0. 982 and 0. 991, respectively). The reference value of normal serum AFP was 0. 8 -10. 5 U/mL. Therefore, the sensitivity of TRFIA for serum AFP is high and covers a wide linear range. It is also highly accurate and is not related with radiolabeled or hazardous chemicals. TRFIA appears to be a useful biochemical ultrami-croanalysis technique worthy of further development.

Key concepts: Medicine, Linear range, Linear relationship, Detection limit, Chromatography, Internal medicine, Chemistry, Statistics

Related papers

Back to paper searchBrowse research topicsOriginal source
Evaluation of Time-resolved Fluoroimmunoassay of Serum AFP — Research Paper | ScholarLens