2011Xiandai yufang yixueRequires access

DETERMINATION OF SEVEN VOLATILE HALOGENATED HYDROCARBONS IN DRINKING WATER BY GAS CHROMATOGRAPHY(GC)WITH SWEEP-CAPTURE

Ji Cao

Open publisher page 0 citations

Abstract

[Objective]To establish a simple and sensitive gas chromatographic method for the simultaneous determination of seven volatile halogenated hydrocarbons in drinking water.[Methods]The separation was performed on a DB—l7 capillary column.Temperature programming and an ECD detector were applied.Retention time was qualitative and external reference method was quantitative.[Results]The detection limits of seven volatile halogenated hydrocarbons varied from 0.01 to 0.06μg/L.The minimum quantitation concentration varied from 0.03 to 0.20μg/L.Mean recovery of volatile halogenated hydrocarbon standards added to water samples varied from 90.6% to 106.9%,the relative standard deviation was 1.78%-6.49%.Six volatile halogenated hydrocarbons,except for trichloroethylene,were detected in 16 water samples.[Conclusion]The method is sensitive,convenient and accurate,and can be applied to determine many kinds of volatile halogenated hydrocarbons in drinking water.

About this research paper

What this paper is about

[Objective]To establish a simple and sensitive gas chromatographic method for the simultaneous determination of seven volatile halogenated hydrocarbons in drinking water.[Methods]The separation was performed on a DB—l7 capillary column.Temperature programming and an ECD detector were applied.Retention time was qualitative and external reference method was quantitative.[Results]The detection limits of seven volatile halogenated hydrocarbons varied from 0.01 to 0.06μg/L.The minimum quantitation concentration varied from 0.03 to 0.20μg/L.Mean recovery of volatile halogenated hydrocarbon standards added to water samples varied from 90.6% to 106.9%,the relative standard deviation was 1.78%-6.49%.Six volatile halogenated hydrocarbons,except for trichloroethylene,were detected in 16 water samples.[Conclusion]The method is sensitive,convenient and accurate,and can be applied to determine many kinds of volatile halogenated hydrocarbons in drinking water.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

[Objective]To establish a simple and sensitive gas chromatographic method for the simultaneous determination of seven volatile halogenated hydrocarbons in drinking water.[Methods]The separation was performed on a DB—l7 capillary column.Temperature programming and an ECD detector were applied.Retention time was qualitative and external reference method was quantitative.[Results]The detection limits of seven volatile halogenated hydrocarbons varied from 0.01 to 0.06μg/L.The minimum quantitation concentration varied from 0.03 to 0.20μg/L.Mean recovery of volatile halogenated hydrocarbon standards added to water samples varied from 90.6% to 106.9%,the relative standard deviation was 1.78%-6.49%.Six volatile halogenated hydrocarbons,except for trichloroethylene,were detected in 16 water samples.[Conclusion]The method is sensitive,convenient and accurate,and can be applied to determine many kinds of volatile halogenated hydrocarbons in drinking water.

Key concepts: Chemistry, Chromatography, Gas chromatography, Trichloroethylene, Hydrocarbon, Relative standard deviation, Electron capture detector, Detection limit

Related papers

Back to paper searchBrowse research topicsOriginal source
DETERMINATION OF SEVEN VOLATILE HALOGENATED HYDROCARBONS IN DRINKING WATER BY GAS CHROMATOGRAPHY(GC)WITH SWEEP-CAPTURE — Research Paper | ScholarLens