1987Journal of Shaanxi Normal UniversityRequires access

CHEMILUMINESCENCE ANALYSIS WITH INORGANIC COUPLING REACTION VI DETERMINATION OF TRACE MOLYBDENUM(VI)IONS BY THE KINETICS CHEMILUMINESCENCE METHOD OF KIO_3-KI-LUMINOL SYSTEM

LU Jiu-ru

Open publisher page 0 citations

Abstract

In the present paper,a chemiluminescence kinetic method is described for the determination of trace Mo(Ⅵ)ions based on its accelerating effect on the iodate-iodide reaction.The chemiluminescence signal arose from the reaction of luminol-I_2.Trace Mo in the range 0.01-1 μg/ml was determined with relative standard deviation of about 4%.A method for the separation of Mo(Ⅵ)ions from large amount of interference ions by an-ion exchange resin was used.The Mo was determined in the samples of mixing water and the result is satisfactory.

About this research paper

What this paper is about

In the present paper,a chemiluminescence kinetic method is described for the determination of trace Mo(Ⅵ)ions based on its accelerating effect on the iodate-iodide reaction.The chemiluminescence signal arose from the reaction of luminol-I_2.Trace Mo in the range 0.01-1 μg/ml was determined with relative standard deviation of about 4%.A method for the separation of Mo(Ⅵ)ions from large amount of interference ions by an-ion exchange resin was used.The Mo was determined in the samples of mixing water and the result is satisfactory.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In the present paper,a chemiluminescence kinetic method is described for the determination of trace Mo(Ⅵ)ions based on its accelerating effect on the iodate-iodide reaction.The chemiluminescence signal arose from the reaction of luminol-I_2.Trace Mo in the range 0.01-1 μg/ml was determined with relative standard deviation of about 4%.A method for the separation of Mo(Ⅵ)ions from large amount of interference ions by an-ion exchange resin was used.The Mo was determined in the samples of mixing water and the result is satisfactory.

Key concepts: Chemiluminescence, Chemistry, Luminol, Iodate, Iodide, Ion, Molybdenum, Inorganic chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
CHEMILUMINESCENCE ANALYSIS WITH INORGANIC COUPLING REACTION VI DETERMINATION OF TRACE MOLYBDENUM(VI)IONS BY THE KINETICS CHEMILUMINESCENCE METHOD OF KIO_3-KI-LUMINOL SYSTEM — Research Paper | ScholarLens