2012Unpublished venueRequires access

Radiation dose reduction with cine segment technique in abdominal CT scan

SU Shou-hon

Open publisher page 0 citations

Abstract

Objective To evaluate the value of low-dose multi-slice CT(MSCT) scanning with smart-mA and Cine Segment technique in radiation dose reduction in abdominal CT scan.Methods A total of 54 patients with abdominal CT scan were divided into three groups,Group A(Smart-mA scanning with 120 kV,n=20),Group B(Smart-mA with Noise Index(NI) =8;Cine scanning with 120 kV;n=16) and Group C(Smart-mA,NI=8;Cine segment scanning with 120 kV;n=8).Radiation dose,and quality score and noise of image were compared.Results There was no significant difference in image quality score among the 3 groups.Image noise in Group C was significant higher than those in the other 2 groups after contrast injection(P0.01).However,significant reduction of radiation dose by 47% revealed in Group C when comparing with that in Group A;and by 25% when comparing with that in Group A(P0.01).Conclusion Smart-mA and Cine Segment scanning techniques effectively reduce the radiation dose in abdominal CT scan.

About this research paper

What this paper is about

Objective To evaluate the value of low-dose multi-slice CT(MSCT) scanning with smart-mA and Cine Segment technique in radiation dose reduction in abdominal CT scan.Methods A total of 54 patients with abdominal CT scan were divided into three groups,Group A(Smart-mA scanning with 120 kV,n=20),Group B(Smart-mA with Noise Index(NI) =8;Cine scanning with 120 kV;n=16) and Group C(Smart-mA,NI=8;Cine segment scanning with 120 kV;n=8).Radiation dose,and quality score and noise of image were compared.Results There was no significant difference in image quality score among the 3 groups.Image noise in Group C was significant higher than those in the other 2 groups after contrast injection(P0.01).However,significant reduction of radiation dose by 47% revealed in Group C when comparing with that in Group A;and by 25% when comparing with that in Group A(P0.01).Conclusion Smart-mA and Cine Segment scanning techniques effectively reduce the radiation dose in abdominal CT scan.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To evaluate the value of low-dose multi-slice CT(MSCT) scanning with smart-mA and Cine Segment technique in radiation dose reduction in abdominal CT scan.Methods A total of 54 patients with abdominal CT scan were divided into three groups,Group A(Smart-mA scanning with 120 kV,n=20),Group B(Smart-mA with Noise Index(NI) =8;Cine scanning with 120 kV;n=16) and Group C(Smart-mA,NI=8;Cine segment scanning with 120 kV;n=8).Radiation dose,and quality score and noise of image were compared.Results There was no significant difference in image quality score among the 3 groups.Image noise in Group C was significant higher than those in the other 2 groups after contrast injection(P0.01).However,significant reduction of radiation dose by 47% revealed in Group C when comparing with that in Group A;and by 25% when comparing with that in Group A(P0.01).Conclusion Smart-mA and Cine Segment scanning techniques effectively reduce the radiation dose in abdominal CT scan.

Key concepts: Nuclear medicine, Radiation dose, Medicine, Image noise, Image quality, Computed tomography, Radiation exposure, Radiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Radiation dose reduction with cine segment technique in abdominal CT scan — Research Paper | ScholarLens