2008Metallurgical AnalysisRequires access

Dual-indicator reaction spectrophotometry for the determination of trace manganese with Mn(II)-brillant green-PAN catalytic system

Dengming Sun

Open publisher page 0 citations

Abstract

A new dual-wavelength dual-indicator catalytic kinetic spectrophotometric method for the determination of manganese was studied.The method is based on the catalytic effect of trace activated manganese(Ⅱ) on the oxidation of brilliant green and 1-(2-pyridylazo)-2-naphthol by patassium periodate in Na2HPO4-KH2PO4 medium.The absorbance was measured at 630 nm and 430 nm.The difference of absorbance between catalytic and non-catalytic system was obtained.Manganese(Ⅱ) concentration was linear with the sum of the absorbance difference.The linear range for the determination of manganese is 0.000 10-0.005 0 μg/mL and the detection limit is 2.4×10-11 g/mL.This method has been successively applied in the determination of trace manganese in water,giving the addition standard recoveries from 96.9% to 101.6% and the RSD up to 2.0%.

About this research paper

What this paper is about

A new dual-wavelength dual-indicator catalytic kinetic spectrophotometric method for the determination of manganese was studied.The method is based on the catalytic effect of trace activated manganese(Ⅱ) on the oxidation of brilliant green and 1-(2-pyridylazo)-2-naphthol by patassium periodate in Na2HPO4-KH2PO4 medium.The absorbance was measured at 630 nm and 430 nm.The difference of absorbance between catalytic and non-catalytic system was obtained.Manganese(Ⅱ) concentration was linear with the sum of the absorbance difference.The linear range for the determination of manganese is 0.000 10-0.005 0 μg/mL and the detection limit is 2.4×10-11 g/mL.This method has been successively applied in the determination of trace manganese in water,giving the addition standard recoveries from 96.9% to 101.6% and the RSD up to 2.0%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new dual-wavelength dual-indicator catalytic kinetic spectrophotometric method for the determination of manganese was studied.The method is based on the catalytic effect of trace activated manganese(Ⅱ) on the oxidation of brilliant green and 1-(2-pyridylazo)-2-naphthol by patassium periodate in Na2HPO4-KH2PO4 medium.The absorbance was measured at 630 nm and 430 nm.The difference of absorbance between catalytic and non-catalytic system was obtained.Manganese(Ⅱ) concentration was linear with the sum of the absorbance difference.The linear range for the determination of manganese is 0.000 10-0.005 0 μg/mL and the detection limit is 2.4×10-11 g/mL.This method has been successively applied in the determination of trace manganese in water,giving the addition standard recoveries from 96.9% to 101.6% and the RSD up to 2.0%.

Key concepts: Absorbance, Manganese, Potassium periodate, Spectrophotometry, Chemistry, Catalysis, Detection limit, Linear range

Related papers

Back to paper searchBrowse research topicsOriginal source
Dual-indicator reaction spectrophotometry for the determination of trace manganese with Mn(II)-brillant green-PAN catalytic system — Research Paper | ScholarLens