2012Journal of Analytical ScienceRequires access

Dual-Wavelength and Dual-Indicator Catalytic Spectrophotometry for Determination of Trace Manganese(II)

Qing-ren Zhu

Open publisher page 0 citations

Abstract

A new method of dual-wavelength dual-indicator catalytic kinetic spectrophotometry for the determination of trace manganese(Ⅱ)in H2SO4medium was established.The method was based on the manganese(Ⅱ)catalyzing oxidation of brilliant green and acid chrome blue K by KIO4in the presence of nitrilotriacetic acid as an activator.The absorbance of catalytic and uncatalytic systems were measured at 430nm and 630nm,respectively.Under the optimum conditions,the linear range for the determination of trace manganese(Ⅱ)was 0.00200~0.0300μg/mL.The detection limit was 1.2×10-11 g/mL.The method has been applied to the determination of trace manganese(Ⅱ)in tea and waste water with satisfactory results.

About this research paper

What this paper is about

A new method of dual-wavelength dual-indicator catalytic kinetic spectrophotometry for the determination of trace manganese(Ⅱ)in H2SO4medium was established.The method was based on the manganese(Ⅱ)catalyzing oxidation of brilliant green and acid chrome blue K by KIO4in the presence of nitrilotriacetic acid as an activator.The absorbance of catalytic and uncatalytic systems were measured at 430nm and 630nm,respectively.Under the optimum conditions,the linear range for the determination of trace manganese(Ⅱ)was 0.00200~0.0300μg/mL.The detection limit was 1.2×10-11 g/mL.The method has been applied to the determination of trace manganese(Ⅱ)in tea and waste water with satisfactory results.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new method of dual-wavelength dual-indicator catalytic kinetic spectrophotometry for the determination of trace manganese(Ⅱ)in H2SO4medium was established.The method was based on the manganese(Ⅱ)catalyzing oxidation of brilliant green and acid chrome blue K by KIO4in the presence of nitrilotriacetic acid as an activator.The absorbance of catalytic and uncatalytic systems were measured at 430nm and 630nm,respectively.Under the optimum conditions,the linear range for the determination of trace manganese(Ⅱ)was 0.00200~0.0300μg/mL.The detection limit was 1.2×10-11 g/mL.The method has been applied to the determination of trace manganese(Ⅱ)in tea and waste water with satisfactory results.

Key concepts: Chemistry, Manganese, Nitrilotriacetic acid, Absorbance, Spectrophotometry, Detection limit, Catalysis, Linear range

Related papers

Back to paper searchBrowse research topicsOriginal source
Dual-Wavelength and Dual-Indicator Catalytic Spectrophotometry for Determination of Trace Manganese(II) — Research Paper | ScholarLens