2009•PubMedRequires access

[Clinical stability of immediate load of domestic micro-titanium screws for anchorage in orthodontics].

Qing-zhong Zheng, Xing-qian Xie, Xue-mei Xie, Jian Wang, Xiaojia Yu

Open publisher page 1 citations

Abstract

PURPOSE: To investigate the immediate load stability of domestic micro-titanium screws for anchorage in orthodontics. METHODS: Adult orthodontic patients needing the greatest anchorage were included in the study. Domestic micro-titanium screws were used to be orthodontic anchorage, immediate implantation and loading were conducted. RESULTS: A total of 52 implants of domestic micro-titanium anchorage in 20 patients were used. Forty-seven implants were successful in 20 patients,5 failed. The total loading time was 3-8 months. CONCLUSIONS: Domestic micro-titanium implant screws for anchorage can meet the needs of clinical orthodontics. However, immediate loading results in 10.4% failure rate, especially for the implant with a diameter of 1.2mmx7mm. Supported by Science and Technology Development Foundation of Fengxian District, Shanghai Municipality (Grant No. 090602).

About this research paper

What this paper is about

PURPOSE: To investigate the immediate load stability of domestic micro-titanium screws for anchorage in orthodontics. METHODS: Adult orthodontic patients needing the greatest anchorage were included in the study. Domestic micro-titanium screws were used to be orthodontic anchorage, immediate implantation and loading were conducted. RESULTS: A total of 52 implants of domestic micro-titanium anchorage in 20 patients were used. Forty-seven implants were successful in 20 patients,5 failed. The total loading time was 3-8 months. CONCLUSIONS: Domestic micro-titanium implant screws for anchorage can meet the needs of clinical orthodontics. However, immediate loading results in 10.4% failure rate, especially for the implant with a diameter of 1.2mmx7mm. Supported by Science and Technology Development Foundation of Fengxian District, Shanghai Municipality (Grant No. 090602).

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To investigate the immediate load stability of domestic micro-titanium screws for anchorage in orthodontics. METHODS: Adult orthodontic patients needing the greatest anchorage were included in the study. Domestic micro-titanium screws were used to be orthodontic anchorage, immediate implantation and loading were conducted. RESULTS: A total of 52 implants of domestic micro-titanium anchorage in 20 patients were used. Forty-seven implants were successful in 20 patients,5 failed. The total loading time was 3-8 months. CONCLUSIONS: Domestic micro-titanium implant screws for anchorage can meet the needs of clinical orthodontics. However, immediate loading results in 10.4% failure rate, especially for the implant with a diameter of 1.2mmx7mm. Supported by Science and Technology Development Foundation of Fengxian District, Shanghai Municipality (Grant No. 090602).

Key concepts: Implant, Dentistry, Medicine, Titanium, Orthodontics, Materials science, Surgery, Metallurgy

Related papers

Back to paper searchBrowse research topicsOriginal source
[Clinical stability of immediate load of domestic micro-titanium screws for anchorage in orthodontics]. — Research Paper | ScholarLens