2013•Zhongguo yixue yingxiang jishuRequires access

Optimization of image quality and radiation dose in CR ammography

Yue Baorong

Open publisher page 1 citations

Abstract

Objective To investigate the difference of image quality between automatic exposure control(AEC) and manual exposure in CR digital mammography,and to observe the effect of image post-processing on improvement of image quality and dose reduction.Methods CDMAM 3.4 phantom and TORMAM phantom were selected and exposed in a CR system in 5 different phantom thickness.Under each thickness there were 4 dose levels(once automatic and 3 times manual exposures,which corresponded to 80%,60% and 40% dose).Three observers interpreted all the images.Each image was scored twice with unprocessed images and post-processed image.The differences of image quality were compared between 3 lower dose images and 100% dose image.Results The results of image quality figure(IQF) of CDMAM phantom showed the image quality of post-processed images were higher than unprocessed images.Part of the lower dose images exceeded AEC dose image in image quality through post-processing.The dose decreased from 20% to 60% through image post-processing in different equivalent breast thickness.From the results of TORMAM phantom,for the detection of filament details and circular details,the scores increased after post-processing(P0.001).However for the partical details,the effect of image post-processing on image quality was not obvious(P=0.74).Conclusion In CR digital mammography,the image quality can be improved through image post-processing.Radiation dosage can decrease through the image post-processing without reduce of image quality.

About this research paper

What this paper is about

Objective To investigate the difference of image quality between automatic exposure control(AEC) and manual exposure in CR digital mammography,and to observe the effect of image post-processing on improvement of image quality and dose reduction.Methods CDMAM 3.4 phantom and TORMAM phantom were selected and exposed in a CR system in 5 different phantom thickness.Under each thickness there were 4 dose levels(once automatic and 3 times manual exposures,which corresponded to 80%,60% and 40% dose).Three observers interpreted all the images.Each image was scored twice with unprocessed images and post-processed image.The differences of image quality were compared between 3 lower dose images and 100% dose image.Results The results of image quality figure(IQF) of CDMAM phantom showed the image quality of post-processed images were higher than unprocessed images.Part of the lower dose images exceeded AEC dose image in image quality through post-processing.The dose decreased from 20% to 60% through image post-processing in different equivalent breast thickness.From the results of TORMAM phantom,for the detection of filament details and circular details,the scores increased after post-processing(P0.001).However for the partical details,the effect of image post-processing on image quality was not obvious(P=0.74).Conclusion In CR digital mammography,the image quality can be improved through image post-processing.Radiation dosage can decrease through the image post-processing without reduce of image quality.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To investigate the difference of image quality between automatic exposure control(AEC) and manual exposure in CR digital mammography,and to observe the effect of image post-processing on improvement of image quality and dose reduction.Methods CDMAM 3.4 phantom and TORMAM phantom were selected and exposed in a CR system in 5 different phantom thickness.Under each thickness there were 4 dose levels(once automatic and 3 times manual exposures,which corresponded to 80%,60% and 40% dose).Three observers interpreted all the images.Each image was scored twice with unprocessed images and post-processed image.The differences of image quality were compared between 3 lower dose images and 100% dose image.Results The results of image quality figure(IQF) of CDMAM phantom showed the image quality of post-processed images were higher than unprocessed images.Part of the lower dose images exceeded AEC dose image in image quality through post-processing.The dose decreased from 20% to 60% through image post-processing in different equivalent breast thickness.From the results of TORMAM phantom,for the detection of filament details and circular details,the scores increased after post-processing(P0.001).However for the partical details,the effect of image post-processing on image quality was not obvious(P=0.74).Conclusion In CR digital mammography,the image quality can be improved through image post-processing.Radiation dosage can decrease through the image post-processing without reduce of image quality.

Key concepts: Image quality, Imaging phantom, Image processing, Medicine, Automatic exposure control, Digital image processing, Radiation dose, Digital mammography

Related papers

Back to paper searchBrowse research topicsOriginal source
Optimization of image quality and radiation dose in CR ammography — Research Paper | ScholarLens