Determination of ephedrine hydrochloride and pseudoephedrine hydrochloride in xiaoerkechuanling granules by HPLC
Jin Yang
Abstract
Jin Yang
Abstract
Aim To develop a method for the determination of ephedrine hydrochloride and pseudoephedrine hydrochloride in Xiao er ke chuan ling Granules by HPLC.Methods Ephedrine hydrochloride and pseudoephedrine hydrochloride were determined by HPLC,Agilent-ODS-3(5 μm,4.6 mm×250 mm) column with Acetonitrile-0.1% H3PO4(5∶ 95) as the mobile phase was used.The flow rate was 1.0 ml·min-1 and the detective wavelength was 207 nm.The column temperature was 25℃.Results A good linear relationship at a range of 0.0306 ~0.306 μg for the ephedrine hydrochloride(r=0.999 9) was obtained.The average recovery was 99.52%,and RSD was 0.39%(n=9).A good linear relationship at a range of 0.0278~0.278 μg for pseudoephedrine hydrochloride(r=0.999 8) was also obtained.The average recovery was 99.49%,and RSD was 0.52%(n=9).Conclusion The method is simple,reproducible and accurate with a goood specificify,and can be used for the quality control of xiaoerkechuanling granules.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Aim To develop a method for the determination of ephedrine hydrochloride and pseudoephedrine hydrochloride in Xiao er ke chuan ling Granules by HPLC.Methods Ephedrine hydrochloride and pseudoephedrine hydrochloride were determined by HPLC,Agilent-ODS-3(5 μm,4.6 mm×250 mm) column with Acetonitrile-0.1% H3PO4(5∶ 95) as the mobile phase was used.The flow rate was 1.0 ml·min-1 and the detective wavelength was 207 nm.The column temperature was 25℃.Results A good linear relationship at a range of 0.0306 ~0.306 μg for the ephedrine hydrochloride(r=0.999 9) was obtained.The average recovery was 99.52%,and RSD was 0.39%(n=9).A good linear relationship at a range of 0.0278~0.278 μg for pseudoephedrine hydrochloride(r=0.999 8) was also obtained.The average recovery was 99.49%,and RSD was 0.52%(n=9).Conclusion The method is simple,reproducible and accurate with a goood specificify,and can be used for the quality control of xiaoerkechuanling granules.
Key concepts: Chromatography, High-performance liquid chromatography, Ephedrine, Pseudoephedrine, Chemistry, Hydrochloride, Linear range, Pharmacology