2004•Analytical LaboratoryRequires access

Simultaneous determination of organic acid and glucose in succinic acid fermentation broth of actinobacillus succinogenes by reversed-phase high performance liquid chromatography (RP-HPLC)

Zhao Xue-ming, Xingang Li

Open publisher page 0 citations

Abstract

A RP-HPLC method for simultaneous determination of organic acid and glucose in succinic acid fermentation broth of Actinobacillus succinogenes was developed. Eclipse XDB-C_8 column(4.6 mm i.d.×150 mm, 5 μm) was used and the mobile phase was 0.005 (mol/L) sulfic acid solution (pH 2.5) with flow rate of 1.0 mL/min. Organic acid and glucose in samples were determined by refractive index detector (RID) within 9 min. The regression equation, the linear range, the correlation coefficient and the detection limit were determined. The relative standard deviation (RSD, n =5) was in the range of 0.41%~0.89%, and the average recovery was in the range of 99.6%~100.8%.

About this research paper

What this paper is about

A RP-HPLC method for simultaneous determination of organic acid and glucose in succinic acid fermentation broth of Actinobacillus succinogenes was developed. Eclipse XDB-C_8 column(4.6 mm i.d.×150 mm, 5 μm) was used and the mobile phase was 0.005 (mol/L) sulfic acid solution (pH 2.5) with flow rate of 1.0 mL/min. Organic acid and glucose in samples were determined by refractive index detector (RID) within 9 min. The regression equation, the linear range, the correlation coefficient and the detection limit were determined. The relative standard deviation (RSD, n =5) was in the range of 0.41%~0.89%, and the average recovery was in the range of 99.6%~100.8%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A RP-HPLC method for simultaneous determination of organic acid and glucose in succinic acid fermentation broth of Actinobacillus succinogenes was developed. Eclipse XDB-C_8 column(4.6 mm i.d.×150 mm, 5 μm) was used and the mobile phase was 0.005 (mol/L) sulfic acid solution (pH 2.5) with flow rate of 1.0 mL/min. Organic acid and glucose in samples were determined by refractive index detector (RID) within 9 min. The regression equation, the linear range, the correlation coefficient and the detection limit were determined. The relative standard deviation (RSD, n =5) was in the range of 0.41%~0.89%, and the average recovery was in the range of 99.6%~100.8%.

Key concepts: Chemistry, Chromatography, Succinic acid, High-performance liquid chromatography, Detection limit, Fermentation, Organic acid, Correlation coefficient

Related papers

Back to paper searchBrowse research topicsOriginal source
Simultaneous determination of organic acid and glucose in succinic acid fermentation broth of actinobacillus succinogenes by reversed-phase high performance liquid chromatography (RP-HPLC) — Research Paper | ScholarLens