2009•Food ScienceRequires access

Determination of Melamine in Liquid Milk by Ion Chromatography with UV Detection

Lina Liang

Open publisher page 0 citations

Abstract

An analytical method using ion chromatography separation coupled with UV detection was developed for the determination of melamine in liquid milk. The procedure was based on extraction of test portions with acetonitrile, cleanup on an OnGuard II RP column to remove fat and filtration through 0.22 μm nylon membrane followed by ion chromatographic analysis of the extracts, using an IonPac CS17 column and UV detection at 240 nm. The calibration curve showed good linearity in the range of 0.02-5.0 mg/L, with a correlation coefficient of 0.99995. The recoveries for melamine spiked liquid milk ranged 82% -94%. The method has the advantages of easiness and quickness, and therefore can be applied for the determination of melamine in liquid milk.

About this research paper

What this paper is about

An analytical method using ion chromatography separation coupled with UV detection was developed for the determination of melamine in liquid milk. The procedure was based on extraction of test portions with acetonitrile, cleanup on an OnGuard II RP column to remove fat and filtration through 0.22 μm nylon membrane followed by ion chromatographic analysis of the extracts, using an IonPac CS17 column and UV detection at 240 nm. The calibration curve showed good linearity in the range of 0.02-5.0 mg/L, with a correlation coefficient of 0.99995. The recoveries for melamine spiked liquid milk ranged 82% -94%. The method has the advantages of easiness and quickness, and therefore can be applied for the determination of melamine in liquid milk.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An analytical method using ion chromatography separation coupled with UV detection was developed for the determination of melamine in liquid milk. The procedure was based on extraction of test portions with acetonitrile, cleanup on an OnGuard II RP column to remove fat and filtration through 0.22 μm nylon membrane followed by ion chromatographic analysis of the extracts, using an IonPac CS17 column and UV detection at 240 nm. The calibration curve showed good linearity in the range of 0.02-5.0 mg/L, with a correlation coefficient of 0.99995. The recoveries for melamine spiked liquid milk ranged 82% -94%. The method has the advantages of easiness and quickness, and therefore can be applied for the determination of melamine in liquid milk.

Key concepts: Melamine, Chromatography, Calibration curve, Chemistry, Detection limit, Ion chromatography, Acetonitrile, Extraction (chemistry)

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Melamine in Liquid Milk by Ion Chromatography with UV Detection — Research Paper | ScholarLens