2010•Modern Medicine HealthRequires access

Determination of content of cinnamic acid and cinnamaldehyde in Bawei Rougui Capsules by HPLC

Wang Chen-hui

Open publisher page 0 citations

Abstract

Objective:To establish a HPLC method for the determination of cinnamaldehyde and cinnamic acid in Bawei Rougui Capsules.Methods:Cinnamic acid and cinnamaldehyde in Bawei Rougui Capsules were determined by HPLC,using kromasil Cl8 column,acetonitrile-0.1%phosphoric acid(22:78) as the mobile phase,the detection wavelength was 285nm.The flow rate was 1.0 mL·min-1.Results:The calibration curves were linear in the range of 0.0042~0.0420 mg·mL-1 for cinnamic acid (r=0.9999) and 0.1224~1.2240 mg· mL-1 for cinnamaldehyde (r=0.9999),respectively.The average recoveries were 98.28%(RSD=1.40%) for cinnamic acid and 98.35%(RSD= 1.32%) for cinnamaldehyde.Conclusion:The method is simple,rapid,accurate and repeatable.It can be used for the quality control of Bawei Rougui Capsules.

About this research paper

What this paper is about

Objective:To establish a HPLC method for the determination of cinnamaldehyde and cinnamic acid in Bawei Rougui Capsules.Methods:Cinnamic acid and cinnamaldehyde in Bawei Rougui Capsules were determined by HPLC,using kromasil Cl8 column,acetonitrile-0.1%phosphoric acid(22:78) as the mobile phase,the detection wavelength was 285nm.The flow rate was 1.0 mL·min-1.Results:The calibration curves were linear in the range of 0.0042~0.0420 mg·mL-1 for cinnamic acid (r=0.9999) and 0.1224~1.2240 mg· mL-1 for cinnamaldehyde (r=0.9999),respectively.The average recoveries were 98.28%(RSD=1.40%) for cinnamic acid and 98.35%(RSD= 1.32%) for cinnamaldehyde.Conclusion:The method is simple,rapid,accurate and repeatable.It can be used for the quality control of Bawei Rougui Capsules.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To establish a HPLC method for the determination of cinnamaldehyde and cinnamic acid in Bawei Rougui Capsules.Methods:Cinnamic acid and cinnamaldehyde in Bawei Rougui Capsules were determined by HPLC,using kromasil Cl8 column,acetonitrile-0.1%phosphoric acid(22:78) as the mobile phase,the detection wavelength was 285nm.The flow rate was 1.0 mL·min-1.Results:The calibration curves were linear in the range of 0.0042~0.0420 mg·mL-1 for cinnamic acid (r=0.9999) and 0.1224~1.2240 mg· mL-1 for cinnamaldehyde (r=0.9999),respectively.The average recoveries were 98.28%(RSD=1.40%) for cinnamic acid and 98.35%(RSD= 1.32%) for cinnamaldehyde.Conclusion:The method is simple,rapid,accurate and repeatable.It can be used for the quality control of Bawei Rougui Capsules.

Key concepts: Cinnamaldehyde, Cinnamic acid, High-performance liquid chromatography, Chromatography, Phosphoric acid, Calibration curve, Content determination, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of content of cinnamic acid and cinnamaldehyde in Bawei Rougui Capsules by HPLC — Research Paper | ScholarLens