2012•Science and Technology of Food IndustryRequires access

Determination of 7 residual monomers in acrylonitrile-styrene plastic by gas chromatography with head space sampler

Wenliang Zhu

Open publisher page 0 citations

Abstract

A reliable method had been developed for determination of 7 residual monomers in acrylonitrile styrene(AS) plastic by headspace-gas chromatography.The samples were completely dissolved into N,N-diethylformamide,and then the gas after achieved equilibrium in the headspace bottle was extracted by headspace injection equipment for gas chromatography analysis.The optimum conditions of gas chromatography and headspace injection were obtained by experiments.The optimum conditions of headspace injection were usage of solvent 3mL,heating temperature 120℃,time for equilibrium 40min.The average recoveries of 7 residual monomers were 95.71%~106.89%,the detection limits were 0.25~1.0mg/kg.The analysis method not only improved detection efficiency,but also cut down the detection cost.Meanwhile,this method was simple,rapid,accurate,and sensitive.

About this research paper

What this paper is about

A reliable method had been developed for determination of 7 residual monomers in acrylonitrile styrene(AS) plastic by headspace-gas chromatography.The samples were completely dissolved into N,N-diethylformamide,and then the gas after achieved equilibrium in the headspace bottle was extracted by headspace injection equipment for gas chromatography analysis.The optimum conditions of gas chromatography and headspace injection were obtained by experiments.The optimum conditions of headspace injection were usage of solvent 3mL,heating temperature 120℃,time for equilibrium 40min.The average recoveries of 7 residual monomers were 95.71%~106.89%,the detection limits were 0.25~1.0mg/kg.The analysis method not only improved detection efficiency,but also cut down the detection cost.Meanwhile,this method was simple,rapid,accurate,and sensitive.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A reliable method had been developed for determination of 7 residual monomers in acrylonitrile styrene(AS) plastic by headspace-gas chromatography.The samples were completely dissolved into N,N-diethylformamide,and then the gas after achieved equilibrium in the headspace bottle was extracted by headspace injection equipment for gas chromatography analysis.The optimum conditions of gas chromatography and headspace injection were obtained by experiments.The optimum conditions of headspace injection were usage of solvent 3mL,heating temperature 120℃,time for equilibrium 40min.The average recoveries of 7 residual monomers were 95.71%~106.89%,the detection limits were 0.25~1.0mg/kg.The analysis method not only improved detection efficiency,but also cut down the detection cost.Meanwhile,this method was simple,rapid,accurate,and sensitive.

Key concepts: Gas chromatography, Bottle, Chromatography, Acrylonitrile, Residual, Monomer, Solvent, Styrene

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of 7 residual monomers in acrylonitrile-styrene plastic by gas chromatography with head space sampler — Research Paper | ScholarLens