Determination of Benzene in Drinking Water by Automated Headspace Gas Chromatography and Solvent Extraction Gas Chromatography

Pin Hao

Open publisher page 0 citations

Abstract

Benzene in drinking water was analyzed by the automated headspace gas chromatography, gas chromatography conditions and headspace conditions were optimized,and compared with the solvent extraction method specified in the National Standard GB / T5750. 8-2006. The automatic headspace gas chromatographic method has good linearity in the range of 0. 00 ~ 105. 00 μg / L,the correlation coefficient was better than 0. 999,with a lowest detection limit of 0. 0 042 mg / L,the recovery rate was 96. 2% ~ 98. 7%,the relative standard deviation of 0. 70%. The experimental results showed that the automatic headspace gas chromatography is more convenient,accurate,sensitive,with less disturbance.

About this research paper

What this paper is about

Benzene in drinking water was analyzed by the automated headspace gas chromatography, gas chromatography conditions and headspace conditions were optimized,and compared with the solvent extraction method specified in the National Standard GB / T5750. 8-2006. The automatic headspace gas chromatographic method has good linearity in the range of 0. 00 ~ 105. 00 μg / L,the correlation coefficient was better than 0. 999,with a lowest detection limit of 0. 0 042 mg / L,the recovery rate was 96. 2% ~ 98. 7%,the relative standard deviation of 0. 70%. The experimental results showed that the automatic headspace gas chromatography is more convenient,accurate,sensitive,with less disturbance.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Benzene in drinking water was analyzed by the automated headspace gas chromatography, gas chromatography conditions and headspace conditions were optimized,and compared with the solvent extraction method specified in the National Standard GB / T5750. 8-2006. The automatic headspace gas chromatographic method has good linearity in the range of 0. 00 ~ 105. 00 μg / L,the correlation coefficient was better than 0. 999,with a lowest detection limit of 0. 0 042 mg / L,the recovery rate was 96. 2% ~ 98. 7%,the relative standard deviation of 0. 70%. The experimental results showed that the automatic headspace gas chromatography is more convenient,accurate,sensitive,with less disturbance.

Key concepts: Gas chromatography, Chromatography, Chemistry, Benzene, Detection limit, Solvent, Extraction (chemistry), Relative standard deviation

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Benzene in Drinking Water by Automated Headspace Gas Chromatography and Solvent Extraction Gas Chromatography — Research Paper | ScholarLens