2010•Chinese Journal of Public Health EngineeringRequires access

Determination of Microcystins in Water by Ultra High Performance Liquid Chromatography-Mass Spectrometry

Huang Wen-pen

Open publisher page 0 citations

Abstract

Objective To establish a method for microcystins in water by ultra-high performance liquid chromatography-tandem mass spectrometry.Methods Ultra high performance liquid chromatography-mass spectrometry combining with solid phase extraction has been employed to enhance the accuracy in the determination of microcystins,such as microcystin-LR.Results The detection limits was 0.04 μg/L,the linear range was 10-1 000 μg/L,average recovery rate was 97.20%,average RSD was 4.71%.Conclusion The results show that the rapid,accurate and sensitive method is suitable for analyzing and monitoring microcystins in water.

About this research paper

What this paper is about

Objective To establish a method for microcystins in water by ultra-high performance liquid chromatography-tandem mass spectrometry.Methods Ultra high performance liquid chromatography-mass spectrometry combining with solid phase extraction has been employed to enhance the accuracy in the determination of microcystins,such as microcystin-LR.Results The detection limits was 0.04 μg/L,the linear range was 10-1 000 μg/L,average recovery rate was 97.20%,average RSD was 4.71%.Conclusion The results show that the rapid,accurate and sensitive method is suitable for analyzing and monitoring microcystins in water.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To establish a method for microcystins in water by ultra-high performance liquid chromatography-tandem mass spectrometry.Methods Ultra high performance liquid chromatography-mass spectrometry combining with solid phase extraction has been employed to enhance the accuracy in the determination of microcystins,such as microcystin-LR.Results The detection limits was 0.04 μg/L,the linear range was 10-1 000 μg/L,average recovery rate was 97.20%,average RSD was 4.71%.Conclusion The results show that the rapid,accurate and sensitive method is suitable for analyzing and monitoring microcystins in water.

Key concepts: Chromatography, Mass spectrometry, Chemistry, Extraction (chemistry), High-performance liquid chromatography, Solid phase extraction, Detection limit, Tandem mass spectrometry

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Microcystins in Water by Ultra High Performance Liquid Chromatography-Mass Spectrometry — Research Paper | ScholarLens