Effective observation of application of stent boost in coronary stent implantation

HU Xi-tia

Open publisher page 0 citations

Abstract

Objective To evaluate the application effect of Stent Boost( SB) in coronary stent implantation. Methods A total of 204 consecutive patients were randomly divided into the observation group( n = 102) and control group( n = 102).Coronary angiography were performed in the two group and coronary stents were implanted which were guided by coronary angiography. Diameter parameters( including maximum,minimum and average) were measured by quantitative coronary angiography( QCA),the ratio( maximum stent diameter( MaxLD)-minimum stent diameter( MinLD)) /MaxLD) was calculated.Stent visibility and the need for post dilatation was assessed at the same time. SB was performed after stent implantation and the parameters were measured in the observation group,stent visibility and the need for post dilatation was assessed. Twentysix patients in the observation group were analyzed by IVUS at the same time. Results The score of stent visibility in the observation group was lower than that of the control group( P 0. 05). Post dilation after stent implantation was performed in 48cases of the observation group and 30 cases in the control group. QCA,SB,IVUS of the two groups measured that the minimum diameter,the maximum diameter,the average diameter and stent eccentricity index had no statistical significance. Pearson correlation analysis showed that QCA and SB,QCA and IVUS,SB and IVUS were in good correlations( r = 0. 772,0. 775,0. 782,respectively,all P 0. 05). Conclusion SB increases the stent visibility and effectively guides the post dilatation. Meanwhile,SB can even take the place of IVUS in the term of measuring tent diameter.

About this research paper

What this paper is about

Objective To evaluate the application effect of Stent Boost( SB) in coronary stent implantation. Methods A total of 204 consecutive patients were randomly divided into the observation group( n = 102) and control group( n = 102).Coronary angiography were performed in the two group and coronary stents were implanted which were guided by coronary angiography. Diameter parameters( including maximum,minimum and average) were measured by quantitative coronary angiography( QCA),the ratio( maximum stent diameter( MaxLD)-minimum stent diameter( MinLD)) /MaxLD) was calculated.Stent visibility and the need for post dilatation was assessed at the same time. SB was performed after stent implantation and the parameters were measured in the observation group,stent visibility and the need for post dilatation was assessed. Twentysix patients in the observation group were analyzed by IVUS at the same time. Results The score of stent visibility in the observation group was lower than that of the control group( P 0. 05). Post dilation after stent implantation was performed in 48cases of the observation group and 30 cases in the control group. QCA,SB,IVUS of the two groups measured that the minimum diameter,the maximum diameter,the average diameter and stent eccentricity index had no statistical significance. Pearson correlation analysis showed that QCA and SB,QCA and IVUS,SB and IVUS were in good correlations( r = 0. 772,0. 775,0. 782,respectively,all P 0. 05). Conclusion SB increases the stent visibility and effectively guides the post dilatation. Meanwhile,SB can even take the place of IVUS in the term of measuring tent diameter.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To evaluate the application effect of Stent Boost( SB) in coronary stent implantation. Methods A total of 204 consecutive patients were randomly divided into the observation group( n = 102) and control group( n = 102).Coronary angiography were performed in the two group and coronary stents were implanted which were guided by coronary angiography. Diameter parameters( including maximum,minimum and average) were measured by quantitative coronary angiography( QCA),the ratio( maximum stent diameter( MaxLD)-minimum stent diameter( MinLD)) /MaxLD) was calculated.Stent visibility and the need for post dilatation was assessed at the same time. SB was performed after stent implantation and the parameters were measured in the observation group,stent visibility and the need for post dilatation was assessed. Twentysix patients in the observation group were analyzed by IVUS at the same time. Results The score of stent visibility in the observation group was lower than that of the control group( P 0. 05). Post dilation after stent implantation was performed in 48cases of the observation group and 30 cases in the control group. QCA,SB,IVUS of the two groups measured that the minimum diameter,the maximum diameter,the average diameter and stent eccentricity index had no statistical significance. Pearson correlation analysis showed that QCA and SB,QCA and IVUS,SB and IVUS were in good correlations( r = 0. 772,0. 775,0. 782,respectively,all P 0. 05). Conclusion SB increases the stent visibility and effectively guides the post dilatation. Meanwhile,SB can even take the place of IVUS in the term of measuring tent diameter.

Key concepts: Stent, Coronary angiography, Medicine, Coronary stent, Angiography, Nuclear medicine, Radiology, Cardiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Effective observation of application of stent boost in coronary stent implantation — Research Paper | ScholarLens