2004•Zhonghua chaosheng yingxiangxue zazhiRequires access

Observation of recent and long-term effects of Radius stent by intravascular ultrasound

Li Jun

Open publisher page 0 citations

Abstract

Objective To investigate the recent and long term effects of Radius stent through intravascular ultrasound(IVUS).Methods The study consisted of 147 coronary disease patients who had implanted self expanding Radius stent in chosen time.Coronary artery angiography and IVUS were performed to evaluate the clinical outcomes of Radius stent before and after the implantation.All the patients were followed up six months approximately after the implantation.Results The implantation success rate and clinical success rate of Radius stent were 99.5% and 98.9% respectively, restenosis rate was 10.8% at follow up examination for 6.4 months.The IVUS measurements showed that the lumen area was extended from 2.7 mm 2 to 5.3 mm 2 after the implantation and stent area was 7.6 mm 2 after about 6.4 months,but since intimal hyperplasia area was 2.6 mm 2,real lumen area was 5.0 mm 2 at follow up, which was a little smaller than that of the stent implantation at once.Conclusions IVUS showed a lower occurrence of restenosis for Radius stent,which is of value to its clinical application.

About this research paper

What this paper is about

Objective To investigate the recent and long term effects of Radius stent through intravascular ultrasound(IVUS).Methods The study consisted of 147 coronary disease patients who had implanted self expanding Radius stent in chosen time.Coronary artery angiography and IVUS were performed to evaluate the clinical outcomes of Radius stent before and after the implantation.All the patients were followed up six months approximately after the implantation.Results The implantation success rate and clinical success rate of Radius stent were 99.5% and 98.9% respectively, restenosis rate was 10.8% at follow up examination for 6.4 months.The IVUS measurements showed that the lumen area was extended from 2.7 mm 2 to 5.3 mm 2 after the implantation and stent area was 7.6 mm 2 after about 6.4 months,but since intimal hyperplasia area was 2.6 mm 2,real lumen area was 5.0 mm 2 at follow up, which was a little smaller than that of the stent implantation at once.Conclusions IVUS showed a lower occurrence of restenosis for Radius stent,which is of value to its clinical application.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To investigate the recent and long term effects of Radius stent through intravascular ultrasound(IVUS).Methods The study consisted of 147 coronary disease patients who had implanted self expanding Radius stent in chosen time.Coronary artery angiography and IVUS were performed to evaluate the clinical outcomes of Radius stent before and after the implantation.All the patients were followed up six months approximately after the implantation.Results The implantation success rate and clinical success rate of Radius stent were 99.5% and 98.9% respectively, restenosis rate was 10.8% at follow up examination for 6.4 months.The IVUS measurements showed that the lumen area was extended from 2.7 mm 2 to 5.3 mm 2 after the implantation and stent area was 7.6 mm 2 after about 6.4 months,but since intimal hyperplasia area was 2.6 mm 2,real lumen area was 5.0 mm 2 at follow up, which was a little smaller than that of the stent implantation at once.Conclusions IVUS showed a lower occurrence of restenosis for Radius stent,which is of value to its clinical application.

Key concepts: Intravascular ultrasound, Medicine, Restenosis, Stent, Lumen (anatomy), Coronary angiography, Radiology, Intimal hyperplasia

Related papers

Back to paper searchBrowse research topicsOriginal source
Observation of recent and long-term effects of Radius stent by intravascular ultrasound — Research Paper | ScholarLens