Detecting Oleanolic and Ursolic Acid with UPLC in Chaenomelis Fructus from Xuancheng

Chenchen Zhu

Open publisher page 0 citations

Abstract

OBJECTIVE To transform and develop high performance liquid chromatograph(HPLC),to establish ultra performance liquid chromatography(UPLC) for determinating the contents of oleanolicacid(OA) and ursolicacid(UA) in Chaenomelis Fructus and to compare UPLC with HPLC.METHODS In the UPLC,ACQUITY UPLC TM BEHC18 column(100 mm×2.1 mm,1.7 μm) was adopted,and the column temperature was 25℃.The mobile phase consisted of methanol-water-glacial acetic acid-triethylamine(254∶46∶0.1∶0.05) with a flow rate of 0.3mL/min.The detection wave length was 210nm,and injection volume was 1 μL in UPLC system.A Shim-pack CLC-ODS(M) column(250mm×4.6mm,5μm) was utilized in HPLC system,and a mixture of methanol-water-glacial acetic acid-triethylamine(265∶35∶0.1∶0.05) was regarded as mobile phase with a flow rate of 0.6mL/min.The Injection volume of HPLC was 20μL.RESULTS The content of oleanolicacid(OA) and ursolicacid(UA) in Chaenomelis Fructus of different picking time detected by HPLC was almost as same as that by UPLC.Compared with HPLC,UPLC provided shorter analysis time,cost less solvent consumption with better sensitivity.CONCLUSION UPLC may replace HPLC for the determination of OA and UA in Chaenomelis Fructus.

About this research paper

What this paper is about

OBJECTIVE To transform and develop high performance liquid chromatograph(HPLC),to establish ultra performance liquid chromatography(UPLC) for determinating the contents of oleanolicacid(OA) and ursolicacid(UA) in Chaenomelis Fructus and to compare UPLC with HPLC.METHODS In the UPLC,ACQUITY UPLC TM BEHC18 column(100 mm×2.1 mm,1.7 μm) was adopted,and the column temperature was 25℃.The mobile phase consisted of methanol-water-glacial acetic acid-triethylamine(254∶46∶0.1∶0.05) with a flow rate of 0.3mL/min.The detection wave length was 210nm,and injection volume was 1 μL in UPLC system.A Shim-pack CLC-ODS(M) column(250mm×4.6mm,5μm) was utilized in HPLC system,and a mixture of methanol-water-glacial acetic acid-triethylamine(265∶35∶0.1∶0.05) was regarded as mobile phase with a flow rate of 0.6mL/min.The Injection volume of HPLC was 20μL.RESULTS The content of oleanolicacid(OA) and ursolicacid(UA) in Chaenomelis Fructus of different picking time detected by HPLC was almost as same as that by UPLC.Compared with HPLC,UPLC provided shorter analysis time,cost less solvent consumption with better sensitivity.CONCLUSION UPLC may replace HPLC for the determination of OA and UA in Chaenomelis Fructus.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE To transform and develop high performance liquid chromatograph(HPLC),to establish ultra performance liquid chromatography(UPLC) for determinating the contents of oleanolicacid(OA) and ursolicacid(UA) in Chaenomelis Fructus and to compare UPLC with HPLC.METHODS In the UPLC,ACQUITY UPLC TM BEHC18 column(100 mm×2.1 mm,1.7 μm) was adopted,and the column temperature was 25℃.The mobile phase consisted of methanol-water-glacial acetic acid-triethylamine(254∶46∶0.1∶0.05) with a flow rate of 0.3mL/min.The detection wave length was 210nm,and injection volume was 1 μL in UPLC system.A Shim-pack CLC-ODS(M) column(250mm×4.6mm,5μm) was utilized in HPLC system,and a mixture of methanol-water-glacial acetic acid-triethylamine(265∶35∶0.1∶0.05) was regarded as mobile phase with a flow rate of 0.6mL/min.The Injection volume of HPLC was 20μL.RESULTS The content of oleanolicacid(OA) and ursolicacid(UA) in Chaenomelis Fructus of different picking time detected by HPLC was almost as same as that by UPLC.Compared with HPLC,UPLC provided shorter analysis time,cost less solvent consumption with better sensitivity.CONCLUSION UPLC may replace HPLC for the determination of OA and UA in Chaenomelis Fructus.

Key concepts: High-performance liquid chromatography, Chromatography, Chemistry, Triethylamine, Acetic acid, Methanol, Biochemistry, Organic chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Detecting Oleanolic and Ursolic Acid with UPLC in Chaenomelis Fructus from Xuancheng — Research Paper | ScholarLens