Diagnostic value of 64-detector spiral CT angiography for dissecting aneurysm of aorta
Jiawen Zhang
Abstract
Jiawen Zhang
Abstract
Objective:To evaluate clinical application value of 64-detector spiral CT angiography for dissecting aneurysm of aorta.Methods:11 cases was studied with 64-detector spiral CT.There were 8 man and 3 women,with the mean age of 51.6 years.The volume data was transferred to AW4.2 workstation for imaging post-processing including VR,MIP,MPR.Results:①The time of 64-detector spiral CT scan was 7~10s;②Three patients with De BackeyⅠ type aortic dissection,Eight patients with De Backey Ⅲ aortic dissection;③The whole aorta and principal branches of 11 patients were demonstrated well by 64-detector spiral CT angiography;④The true lumen,false lumen,intimal flap,location and extend of dissecting aneurysm were showed in all patients satisfactorily;⑤Three patients with superior mesenteric artery stenosis,two patients with superior mesenteric artery dissection,five patients with renal artery stenosis;⑥One patient after endovascular stent placement,no endoleakage appear,location of endovascular stent was normal.Conclusion:64-detector spiral CT angiography can display clearly dissecting aneurysm of aorta.It may supply valuable information for the diagnosis of the dissecting aneurysm of aorta and especially for surgical operation.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective:To evaluate clinical application value of 64-detector spiral CT angiography for dissecting aneurysm of aorta.Methods:11 cases was studied with 64-detector spiral CT.There were 8 man and 3 women,with the mean age of 51.6 years.The volume data was transferred to AW4.2 workstation for imaging post-processing including VR,MIP,MPR.Results:①The time of 64-detector spiral CT scan was 7~10s;②Three patients with De BackeyⅠ type aortic dissection,Eight patients with De Backey Ⅲ aortic dissection;③The whole aorta and principal branches of 11 patients were demonstrated well by 64-detector spiral CT angiography;④The true lumen,false lumen,intimal flap,location and extend of dissecting aneurysm were showed in all patients satisfactorily;⑤Three patients with superior mesenteric artery stenosis,two patients with superior mesenteric artery dissection,five patients with renal artery stenosis;⑥One patient after endovascular stent placement,no endoleakage appear,location of endovascular stent was normal.Conclusion:64-detector spiral CT angiography can display clearly dissecting aneurysm of aorta.It may supply valuable information for the diagnosis of the dissecting aneurysm of aorta and especially for surgical operation.
Key concepts: Medicine, Aneurysm, Radiology, Angiography, Aorta, Stenosis, Lumen (anatomy), Dissection (medical)