Determination of Trace Bromate in Water by UV Spectrophotometry

Jianqiu Chen

Open publisher page 0 citations

Abstract

A simple ultraviolet-spectrophotometric method was developed for the Determination of bromate in water samples.Bromate reacts with iodide in acidic media to produce tri-iodide which has a UV absorbance at 288 nm and thus can be monitored spectrophotometrically.The recovery of bromate Determination by UV spectrophotometry was 98%~102%,and the relative standard deviation was 1.7%(n=9).The calibration equation for bromate analysis has a good linearity with regression coefficient of 0.9991.The detection of limit for bromate was 4.0 μg/L,showing that the method can meet the testing requirement.

About this research paper

What this paper is about

A simple ultraviolet-spectrophotometric method was developed for the Determination of bromate in water samples.Bromate reacts with iodide in acidic media to produce tri-iodide which has a UV absorbance at 288 nm and thus can be monitored spectrophotometrically.The recovery of bromate Determination by UV spectrophotometry was 98%~102%,and the relative standard deviation was 1.7%(n=9).The calibration equation for bromate analysis has a good linearity with regression coefficient of 0.9991.The detection of limit for bromate was 4.0 μg/L,showing that the method can meet the testing requirement.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A simple ultraviolet-spectrophotometric method was developed for the Determination of bromate in water samples.Bromate reacts with iodide in acidic media to produce tri-iodide which has a UV absorbance at 288 nm and thus can be monitored spectrophotometrically.The recovery of bromate Determination by UV spectrophotometry was 98%~102%,and the relative standard deviation was 1.7%(n=9).The calibration equation for bromate analysis has a good linearity with regression coefficient of 0.9991.The detection of limit for bromate was 4.0 μg/L,showing that the method can meet the testing requirement.

Key concepts: Bromate, Absorbance, Spectrophotometry, Chemistry, Iodide, Detection limit, Ultraviolet, Calibration curve