A new color-fading spectrophotometric method for determining trace amount of bromate was developed.It was based on the oxidation of toluidine blue by potassium bromate in a dilute acidic solution containing 6 mol/L of HCl.This method was implemented at the room temperature.The optimum experimental conditions for the determination were found.The detection limit for bromate was 3.62×10-4 g/L,and the linear range of the determination was 0.1~0.9 μg/mL with the absorbance measured at 625 nm.The method was applied to the determination of trace amount of bromate in chemical reagents with satisfactory results.

About this research paper

What this paper is about

A new color-fading spectrophotometric method for determining trace amount of bromate was developed.It was based on the oxidation of toluidine blue by potassium bromate in a dilute acidic solution containing 6 mol/L of HCl.This method was implemented at the room temperature.The optimum experimental conditions for the determination were found.The detection limit for bromate was 3.62×10-4 g/L,and the linear range of the determination was 0.1~0.9 μg/mL with the absorbance measured at 625 nm.The method was applied to the determination of trace amount of bromate in chemical reagents with satisfactory results.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new color-fading spectrophotometric method for determining trace amount of bromate was developed.It was based on the oxidation of toluidine blue by potassium bromate in a dilute acidic solution containing 6 mol/L of HCl.This method was implemented at the room temperature.The optimum experimental conditions for the determination were found.The detection limit for bromate was 3.62×10-4 g/L,and the linear range of the determination was 0.1~0.9 μg/mL with the absorbance measured at 625 nm.The method was applied to the determination of trace amount of bromate in chemical reagents with satisfactory results.

Key concepts: Bromate, Potassium bromate, Chemistry, Absorbance, Reagent, Detection limit, Toluidine, Spectrophotometry

Related papers

Back to paper searchBrowse research topicsOriginal source
Study on spectrophotometric determination of trace amount of bromate by oxidative decoloration of toluidine blue — Research Paper | ScholarLens