2010•IEEE Transactions on Power ElectronicsRequires access

Research on Deadbeat Control in the Active Power Filter

Zhu Jun-xing

Open publisher page 1 citations

Abstract

A compound harmonic current detection of the active power filter(APF),including the load current detection and the source current detection is proposed.A novel deadbeat control strategy is proposed for the APF with four-bridge topology.Based on the analysis of the topology of the system,a complete mathematical model is established.The coupling a-mong the output harmonic currents of every phase in the APF is analyzed,and the decoupling method is presented.The simulation and experimental results demonstrate the effectiveness of the proposed compound harmonic current detection method and the deadbeat control strategy.

About this research paper

What this paper is about

A compound harmonic current detection of the active power filter(APF),including the load current detection and the source current detection is proposed.A novel deadbeat control strategy is proposed for the APF with four-bridge topology.Based on the analysis of the topology of the system,a complete mathematical model is established.The coupling a-mong the output harmonic currents of every phase in the APF is analyzed,and the decoupling method is presented.The simulation and experimental results demonstrate the effectiveness of the proposed compound harmonic current detection method and the deadbeat control strategy.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A compound harmonic current detection of the active power filter(APF),including the load current detection and the source current detection is proposed.A novel deadbeat control strategy is proposed for the APF with four-bridge topology.Based on the analysis of the topology of the system,a complete mathematical model is established.The coupling a-mong the output harmonic currents of every phase in the APF is analyzed,and the decoupling method is presented.The simulation and experimental results demonstrate the effectiveness of the proposed compound harmonic current detection method and the deadbeat control strategy.

Key concepts: Active power filter, Decoupling (probability), Active filter, Control theory (sociology), Topology (electrical circuits), Harmonic, Three-phase, Current (fluid)

Related papers

Back to paper searchBrowse research topicsOriginal source