2011•Power System Protection and ControlOpen access

Study on a deadbeat control scheme for three-phase four-leg shunt active power filter

Rui Zhou

Open full text 0 citations

Abstract

Based on the study of four-leg shunt active power filter(APF),harmonic detection method for three-phase four-wire system and the control strategy for APF are researched respectively.To calculate the instruction current,the ip-iq harmonic current detection method based on instantaneous reactive power theory is adopted.The paper also discusses the principle of the deadbeat control scheme in detail and derives the deadbeat control model theoretically.The principle and realization steps of 3-dimension SVPWM and the predictive method for compensation currents are researched as well.Experiments verify the feasibility of the deadbeat control system.Advantages and the existing problems of the deadbeat control system are summarized conclusively.

About this research paper

What this paper is about

Based on the study of four-leg shunt active power filter(APF),harmonic detection method for three-phase four-wire system and the control strategy for APF are researched respectively.To calculate the instruction current,the ip-iq harmonic current detection method based on instantaneous reactive power theory is adopted.The paper also discusses the principle of the deadbeat control scheme in detail and derives the deadbeat control model theoretically.The principle and realization steps of 3-dimension SVPWM and the predictive method for compensation currents are researched as well.Experiments verify the feasibility of the deadbeat control system.Advantages and the existing problems of the deadbeat control system are summarized conclusively.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Based on the study of four-leg shunt active power filter(APF),harmonic detection method for three-phase four-wire system and the control strategy for APF are researched respectively.To calculate the instruction current,the ip-iq harmonic current detection method based on instantaneous reactive power theory is adopted.The paper also discusses the principle of the deadbeat control scheme in detail and derives the deadbeat control model theoretically.The principle and realization steps of 3-dimension SVPWM and the predictive method for compensation currents are researched as well.Experiments verify the feasibility of the deadbeat control system.Advantages and the existing problems of the deadbeat control system are summarized conclusively.

Key concepts: Control theory (sociology), Active power filter, Shunt (medical), AC power, Compensation (psychology), Three-phase, Harmonic, Active filter

Related papers

Back to paper searchBrowse research topicsOriginal source
Study on a deadbeat control scheme for three-phase four-leg shunt active power filter — Research Paper | ScholarLens