2013Chinese Journal of Analysis LaboratoryRequires access

UPLC-MS/MS for simultaneous determination of three sulfonylurea herbicide residues in soil

Fan Li

Open publisher page 0 citations

Abstract

A method detecting 3 herbicide residues including thifensulfuron-methyl,tribenuron methyl,chlorimuron-ethyl in soil was established by using QuEChERS-ultra-high performance liquid chromatographytandem mass spectrometry(UPLC-MS / MS).Soil samples were rapidly extracted by acetonitrile,purified by C 18 solid dispersant.The purified liquid was analysed by UPLC-MS / MS in multiple reaction monitoring(MRM) mode,and 0.1% formic acid in water and acetonitrile were used as mobile phase to complete gradient elution.The calibration curves of three herbicides have good linear correlation in the concentration range of 0.5 ~ 500 ng / mL(R = 0.996 ~ 0.999).The spike recovery experiments were carried out at levels of 10 μg / kg and 50 μg / kg,the average recoveries were between 81.4% and 92.9%,RSD were 5.5% ~ 10.6%,and the method detection limit(S / N = 3) were 0.12 ~ 0.16 μg / kg.The results showed that the method could be used for the detection of the actual soil samples.

About this research paper

What this paper is about

A method detecting 3 herbicide residues including thifensulfuron-methyl,tribenuron methyl,chlorimuron-ethyl in soil was established by using QuEChERS-ultra-high performance liquid chromatographytandem mass spectrometry(UPLC-MS / MS).Soil samples were rapidly extracted by acetonitrile,purified by C 18 solid dispersant.The purified liquid was analysed by UPLC-MS / MS in multiple reaction monitoring(MRM) mode,and 0.1% formic acid in water and acetonitrile were used as mobile phase to complete gradient elution.The calibration curves of three herbicides have good linear correlation in the concentration range of 0.5 ~ 500 ng / mL(R = 0.996 ~ 0.999).The spike recovery experiments were carried out at levels of 10 μg / kg and 50 μg / kg,the average recoveries were between 81.4% and 92.9%,RSD were 5.5% ~ 10.6%,and the method detection limit(S / N = 3) were 0.12 ~ 0.16 μg / kg.The results showed that the method could be used for the detection of the actual soil samples.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method detecting 3 herbicide residues including thifensulfuron-methyl,tribenuron methyl,chlorimuron-ethyl in soil was established by using QuEChERS-ultra-high performance liquid chromatographytandem mass spectrometry(UPLC-MS / MS).Soil samples were rapidly extracted by acetonitrile,purified by C 18 solid dispersant.The purified liquid was analysed by UPLC-MS / MS in multiple reaction monitoring(MRM) mode,and 0.1% formic acid in water and acetonitrile were used as mobile phase to complete gradient elution.The calibration curves of three herbicides have good linear correlation in the concentration range of 0.5 ~ 500 ng / mL(R = 0.996 ~ 0.999).The spike recovery experiments were carried out at levels of 10 μg / kg and 50 μg / kg,the average recoveries were between 81.4% and 92.9%,RSD were 5.5% ~ 10.6%,and the method detection limit(S / N = 3) were 0.12 ~ 0.16 μg / kg.The results showed that the method could be used for the detection of the actual soil samples.

Key concepts: Chemistry, Chromatography, Formic acid, Quechers, Detection limit, High-performance liquid chromatography, Acetonitrile, Calibration curve

Related papers

Back to paper searchBrowse research topicsOriginal source
UPLC-MS/MS for simultaneous determination of three sulfonylurea herbicide residues in soil — Research Paper | ScholarLens