Rapid Determination for Borax in Soymilk by Improved Azomethine H Acid Method
Zheng Hongya
Abstract
Zheng Hongya
Abstract
[Objective]To establish a new method for rapid determination of borax in soymilk. [Method]The commercially available soybean milk were mercerized,carbided,ashed,and then the ash was dissolved with 5 ml 5% HCl,borax were converted into the borate ion. With azomethine H acid as chromogenic agent,the absorbance value was determined at wavelength 420 nm. [Result] The results showed that the linearity is good when boric acid concentration in the sample is 0- 0. 500 mg/ml. The linear correlation coefficient is 0. 999 1,the recovery is 97. 04%- 99. 58%,and the RSD is 1. 53%- 3. 69%,the lowest detection limit concentration is 1. 83 mg/kg. Compared with curcumin spectrophotometry,the difference was not significant (t = 1. 800,P 0. 05). [Conclusion] The law required experimental equipment is simple,avoids the tedious enrichment step,saves a large amount of ethanol,the sensitivity and accuracy can meet the requirement analysis, and is applicable to large quantities of soy milk in borax detection.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
[Objective]To establish a new method for rapid determination of borax in soymilk. [Method]The commercially available soybean milk were mercerized,carbided,ashed,and then the ash was dissolved with 5 ml 5% HCl,borax were converted into the borate ion. With azomethine H acid as chromogenic agent,the absorbance value was determined at wavelength 420 nm. [Result] The results showed that the linearity is good when boric acid concentration in the sample is 0- 0. 500 mg/ml. The linear correlation coefficient is 0. 999 1,the recovery is 97. 04%- 99. 58%,and the RSD is 1. 53%- 3. 69%,the lowest detection limit concentration is 1. 83 mg/kg. Compared with curcumin spectrophotometry,the difference was not significant (t = 1. 800,P 0. 05). [Conclusion] The law required experimental equipment is simple,avoids the tedious enrichment step,saves a large amount of ethanol,the sensitivity and accuracy can meet the requirement analysis, and is applicable to large quantities of soy milk in borax detection.
Key concepts: Borax, Boric acid, Chemistry, Absorbance, Chromogenic, Detection limit, Chromatography, Spectrophotometry