On line supported liquid membrane enrichmentflow injection spectrophotometric determination of trace cadmium(II) in water
Zhengjun Gong
Abstract
Zhengjun Gong
Abstract
An on line supported liquid membrane enrichment-flow injection spectrophotometry for determination of trace cadmium(Ⅱ) in water has been developed,and a flow carrier,hexadecylamine dissolved in kerosene is used in the supported liquid membrane extraction system.Experiment conditions were optimized.The results obtained were as follows: the concentration of HCl is 0.04 mol/L,the concentration of NH4Ac as a reextraction solution is 0.02 mol/L,the concentration of hexadecylamine is 0.02 mol/L,the aperture of PTFE membrane is 0.2 μm,the enrichment time is 20 min.The detection limit for cadmium(Ⅱ) is 0.05 μg/L,the linear range of the determination is 0.10-40 μg/L,and the relative standard deviation(RSD) is 2.38 % for 10 μg/L cadmium(Ⅱ)(n=5).The method can be applied to the determination of trace cadmiun(Ⅱ) in standard water samples and the determination results are agreement with the certified values.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
An on line supported liquid membrane enrichment-flow injection spectrophotometry for determination of trace cadmium(Ⅱ) in water has been developed,and a flow carrier,hexadecylamine dissolved in kerosene is used in the supported liquid membrane extraction system.Experiment conditions were optimized.The results obtained were as follows: the concentration of HCl is 0.04 mol/L,the concentration of NH4Ac as a reextraction solution is 0.02 mol/L,the concentration of hexadecylamine is 0.02 mol/L,the aperture of PTFE membrane is 0.2 μm,the enrichment time is 20 min.The detection limit for cadmium(Ⅱ) is 0.05 μg/L,the linear range of the determination is 0.10-40 μg/L,and the relative standard deviation(RSD) is 2.38 % for 10 μg/L cadmium(Ⅱ)(n=5).The method can be applied to the determination of trace cadmiun(Ⅱ) in standard water samples and the determination results are agreement with the certified values.
Key concepts: Cadmium, Chemistry, Analytical Chemistry (journal), Detection limit, Certified reference materials, Membrane, Trace Amounts, Extraction (chemistry)