2014Mining EngineeringRequires access

Design Calculation of Sintering Chimney Height

Wang Jiecha

Open publisher page 0 citations

Abstract

Combining withtheories and formulas ofdesign calculation of chimneyheightfor main exhausting system of180m2 sintering project,from calculation it can be concluded thatchimney draught and environmental protection requirements are main factors that influence chimney height,among which environmental protectionrequirement is the key factor.Chimney draught asks the limited height is no less than 40m;SO2ground pollutant concentration asks the limited chimney height is no less than 63 m.Nitrogen oxidesground pollutant concentration asks the limited chimney height is no less than 81 m.

About this research paper

What this paper is about

Combining withtheories and formulas ofdesign calculation of chimneyheightfor main exhausting system of180m2 sintering project,from calculation it can be concluded thatchimney draught and environmental protection requirements are main factors that influence chimney height,among which environmental protectionrequirement is the key factor.Chimney draught asks the limited height is no less than 40m;SO2ground pollutant concentration asks the limited chimney height is no less than 63 m.Nitrogen oxidesground pollutant concentration asks the limited chimney height is no less than 81 m.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Combining withtheories and formulas ofdesign calculation of chimneyheightfor main exhausting system of180m2 sintering project,from calculation it can be concluded thatchimney draught and environmental protection requirements are main factors that influence chimney height,among which environmental protectionrequirement is the key factor.Chimney draught asks the limited height is no less than 40m;SO2ground pollutant concentration asks the limited chimney height is no less than 63 m.Nitrogen oxidesground pollutant concentration asks the limited chimney height is no less than 81 m.

Key concepts: Chimney (locomotive), Pollutant, Environmental science, Sintering, Environmental engineering, Engineering, Waste management, Metallurgy

Related papers

Back to paper searchBrowse research topicsOriginal source
Design Calculation of Sintering Chimney Height — Research Paper | ScholarLens