2009•Nanfang dianwang jishuRequires access

Research for the Neutral Point Protection Measures of Voltage Transformer’s Secondary Windings

Fuchang Lin

Open publisher page 0 citations

Abstract

Experimental and simulation studies are carried out on the lightning transfer in the neutral point of the voltage transformer’s secondary winding and the potential difference between two points of ground network in the situations of lightning invasion, direct lightning stroke and power frequency grounding fault. The results show that the risetime of lightning surge wave has obvious influence on the over-voltage level of lightning transmission at the neutral point of the secondary winding, and the breadth values of the level for both the voltage-type and capacitance-type voltage transformer increase rapidly as the risetime of lightning suge wave decreases. The over-voltage level is limited greatly by an arrester, indicating that the ZnO arrester (MOA) can work well for protection against the over-voltage of the neutral point of the secondary winding, but it should be careful to choose suitable rating voltage of the arrester.

About this research paper

What this paper is about

Experimental and simulation studies are carried out on the lightning transfer in the neutral point of the voltage transformer’s secondary winding and the potential difference between two points of ground network in the situations of lightning invasion, direct lightning stroke and power frequency grounding fault. The results show that the risetime of lightning surge wave has obvious influence on the over-voltage level of lightning transmission at the neutral point of the secondary winding, and the breadth values of the level for both the voltage-type and capacitance-type voltage transformer increase rapidly as the risetime of lightning suge wave decreases. The over-voltage level is limited greatly by an arrester, indicating that the ZnO arrester (MOA) can work well for protection against the over-voltage of the neutral point of the secondary winding, but it should be careful to choose suitable rating voltage of the arrester.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Experimental and simulation studies are carried out on the lightning transfer in the neutral point of the voltage transformer’s secondary winding and the potential difference between two points of ground network in the situations of lightning invasion, direct lightning stroke and power frequency grounding fault. The results show that the risetime of lightning surge wave has obvious influence on the over-voltage level of lightning transmission at the neutral point of the secondary winding, and the breadth values of the level for both the voltage-type and capacitance-type voltage transformer increase rapidly as the risetime of lightning suge wave decreases. The over-voltage level is limited greatly by an arrester, indicating that the ZnO arrester (MOA) can work well for protection against the over-voltage of the neutral point of the secondary winding, but it should be careful to choose suitable rating voltage of the arrester.

Key concepts: Lightning arrester, Electrical engineering, Transformer, Ground, Voltage, Surge arrester, Engineering, Electromagnetic coil

Related papers

Back to paper searchBrowse research topicsOriginal source