2009•Guangdong Electric PowerRequires access

Study on Necessity of Overvoltage Protection for Secondary Winding Neutral-point of Voltage Transformer: Test and Numerical Analysis on Lightning Transmission Overvoltage at Secondary Winding Neutral-point

Qi Liu

Open publisher page 0 citations

Abstract

In view of the multiple protection misoperation accidents caused by incorrect breakdown of discharge gap at the secondary winding neutral-point of voltage transformer in Guangdong power grid in recent years,test and theoretical study are made on the necessity of installing overvoltage protection for the secondary winding neutral-point of voltage transformer.Experiments and numerical simulations are carried out to study the lightning transfer overvoltage in the neutral-point of the secondary winding under the situation of lightning invasion.The overvoltage level of lightning transmission at the neutral-point of the secondary winding is determined,and the necessity of the overvoltage protection for the secondary winding neutral-point of voltage transformer is confirmed.

About this research paper

What this paper is about

In view of the multiple protection misoperation accidents caused by incorrect breakdown of discharge gap at the secondary winding neutral-point of voltage transformer in Guangdong power grid in recent years,test and theoretical study are made on the necessity of installing overvoltage protection for the secondary winding neutral-point of voltage transformer.Experiments and numerical simulations are carried out to study the lightning transfer overvoltage in the neutral-point of the secondary winding under the situation of lightning invasion.The overvoltage level of lightning transmission at the neutral-point of the secondary winding is determined,and the necessity of the overvoltage protection for the secondary winding neutral-point of voltage transformer is confirmed.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In view of the multiple protection misoperation accidents caused by incorrect breakdown of discharge gap at the secondary winding neutral-point of voltage transformer in Guangdong power grid in recent years,test and theoretical study are made on the necessity of installing overvoltage protection for the secondary winding neutral-point of voltage transformer.Experiments and numerical simulations are carried out to study the lightning transfer overvoltage in the neutral-point of the secondary winding under the situation of lightning invasion.The overvoltage level of lightning transmission at the neutral-point of the secondary winding is determined,and the necessity of the overvoltage protection for the secondary winding neutral-point of voltage transformer is confirmed.

Key concepts: Overvoltage, Transformer, Electrical engineering, Engineering, Voltage

Related papers

Back to paper searchBrowse research topicsOriginal source
Study on Necessity of Overvoltage Protection for Secondary Winding Neutral-point of Voltage Transformer: Test and Numerical Analysis on Lightning Transmission Overvoltage at Secondary Winding Neutral-point — Research Paper | ScholarLens