RP-HPLC Method Development and Validation of Gallic acid in Polyherbal Tablet Formulation
Kamal Kardani, Nilesh Gurav, Bhavna Solanki, Prateek Patel, Bhavna Patel
Abstract
Kamal Kardani, Nilesh Gurav, Bhavna Solanki, Prateek Patel, Bhavna Patel
Abstract
A new simple, accurate, precise, sensitive and validated RP-HPLC method was developed for the estimation of Gallic acid in bulk and pharmaceutical tablet dosage form. The chromatographic conditions used for the separation was Phenomenex Luna C18 (2) (4.6 x 250mm, 5μ), rheodyne manual injector with capacity of 20µL and mobile phase comprised of Water: Acetonitrile (80: 20%v/v) and pH is maintained at 3.00 using Ophosphoric acid (OPA). The flow rate was 1.0mL/min with detection at 272nm. The retention time was found to be 3.60min. The linearity was found to be in the range of 0.5-50µg/mL for Gallic acid with correlation coefficient of 0.9994. The proposed method is accurate with 99.97% - 100.58 % recovery and precise (%RSD of repeatability, intra-day and inter-day variations were 1.26%, 0.48-0.95%, 0.80-1.83%). The Limit of Detection (LOD) and Limit of Quantification (LOQ) were found to be 0.0178µg/mL and 0.0539µg/mL respectively. The amount of Gallic acid in Polyherbal tablet was found to be 1.63%.
OpenAlex reports 26 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A new simple, accurate, precise, sensitive and validated RP-HPLC method was developed for the estimation of Gallic acid in bulk and pharmaceutical tablet dosage form. The chromatographic conditions used for the separation was Phenomenex Luna C18 (2) (4.6 x 250mm, 5μ), rheodyne manual injector with capacity of 20µL and mobile phase comprised of Water: Acetonitrile (80: 20%v/v) and pH is maintained at 3.00 using Ophosphoric acid (OPA). The flow rate was 1.0mL/min with detection at 272nm. The retention time was found to be 3.60min. The linearity was found to be in the range of 0.5-50µg/mL for Gallic acid with correlation coefficient of 0.9994. The proposed method is accurate with 99.97% - 100.58 % recovery and precise (%RSD of repeatability, intra-day and inter-day variations were 1.26%, 0.48-0.95%, 0.80-1.83%). The Limit of Detection (LOD) and Limit of Quantification (LOQ) were found to be 0.0178µg/mL and 0.0539µg/mL respectively. The amount of Gallic acid in Polyherbal tablet was found to be 1.63%.
Key concepts: Gallic acid, Repeatability, Chromatography, Detection limit, Chemistry, Correlation coefficient, High-performance liquid chromatography, Mathematics