2011•Chinese Journal of Spectroscopy LaboratoryRequires access

Determination of As and Hg in Metal Jewelry by Hydride Generation-Atomic Fluorescence Spectrometry

Chen De

Open publisher page 0 citations

Abstract

The method for the determination of As and Hg in metal jewelry was developed by hydride generation-atomic fluorescence spectrometry.The sample was digested with HNO3 and HCl(V/V,3∶1) with microwave.The detection limit of the method were 0.079μg/L for As,0.037μg/L for Hg,and relative standard deviation of As and Hg were 1.89% and 4.82%,respectively.The recovery of As and Hg were 99.6% and 96.0%,respectively.The method is simple and fast,and suitable for daily inspection of metal jewelry.

About this research paper

What this paper is about

The method for the determination of As and Hg in metal jewelry was developed by hydride generation-atomic fluorescence spectrometry.The sample was digested with HNO3 and HCl(V/V,3∶1) with microwave.The detection limit of the method were 0.079μg/L for As,0.037μg/L for Hg,and relative standard deviation of As and Hg were 1.89% and 4.82%,respectively.The recovery of As and Hg were 99.6% and 96.0%,respectively.The method is simple and fast,and suitable for daily inspection of metal jewelry.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The method for the determination of As and Hg in metal jewelry was developed by hydride generation-atomic fluorescence spectrometry.The sample was digested with HNO3 and HCl(V/V,3∶1) with microwave.The detection limit of the method were 0.079μg/L for As,0.037μg/L for Hg,and relative standard deviation of As and Hg were 1.89% and 4.82%,respectively.The recovery of As and Hg were 99.6% and 96.0%,respectively.The method is simple and fast,and suitable for daily inspection of metal jewelry.

Key concepts: Hydride, Detection limit, Relative standard deviation, Metal, Chemistry, Analytical Chemistry (journal), Mass spectrometry, Fluorescence spectrometry

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of As and Hg in Metal Jewelry by Hydride Generation-Atomic Fluorescence Spectrometry — Research Paper | ScholarLens