2011China Medical HeraldRequires access

The value of transvaginal ultrasonographic examination of the uterine cervix in predicting preterm delivery for pregnant women with threatened preterm labor

Liu Fu-min

Open publisher page 0 citations

Abstract

Objective: To evaluate the value of transvaginal ultrasonographic examination of the uterine cervix in predicting preterm delivery for pregnant women with threatened preterm labor.Methods: Transvaginal ultrasonographic(TVS) was performed in 189 women with threatened preterm labor.Cervical parameters of the ultrasonography were evaluated including cervical length,the presence of funneling,funnel length,funnel width and cervical indexs [(Funnel length +1)/Cervical length].Results: The prevalence of preterm delivery was 34.4%(65/189) in 189 women with threatened preterm labor.A significant association was indicated by logistic regression analysis between the occurrence of preterm delivery and ultrasonographic cervical parameters.But of all ultrasonographic parameters the cervical length were the best predictor of preterm delivery.Receiver operating characteristic curve(ROC) analyses showed that a cervical length of 25 mm was the optimal cut-off to predict the perterm delivery occurrence,the sensitivity,specificity,positive predictive value(PPV) and negative predictive value(NPV) were 67.7%,75.0%,58.7%,81.6%respectively.Conclusion: It is suggested that the transvaginal ultrasonographic measurement of the uterine cervix is an objective and accurate method in predicting preterm delivery for pregnant women with threatened preterm labor.

About this research paper

What this paper is about

Objective: To evaluate the value of transvaginal ultrasonographic examination of the uterine cervix in predicting preterm delivery for pregnant women with threatened preterm labor.Methods: Transvaginal ultrasonographic(TVS) was performed in 189 women with threatened preterm labor.Cervical parameters of the ultrasonography were evaluated including cervical length,the presence of funneling,funnel length,funnel width and cervical indexs [(Funnel length +1)/Cervical length].Results: The prevalence of preterm delivery was 34.4%(65/189) in 189 women with threatened preterm labor.A significant association was indicated by logistic regression analysis between the occurrence of preterm delivery and ultrasonographic cervical parameters.But of all ultrasonographic parameters the cervical length were the best predictor of preterm delivery.Receiver operating characteristic curve(ROC) analyses showed that a cervical length of 25 mm was the optimal cut-off to predict the perterm delivery occurrence,the sensitivity,specificity,positive predictive value(PPV) and negative predictive value(NPV) were 67.7%,75.0%,58.7%,81.6%respectively.Conclusion: It is suggested that the transvaginal ultrasonographic measurement of the uterine cervix is an objective and accurate method in predicting preterm delivery for pregnant women with threatened preterm labor.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective: To evaluate the value of transvaginal ultrasonographic examination of the uterine cervix in predicting preterm delivery for pregnant women with threatened preterm labor.Methods: Transvaginal ultrasonographic(TVS) was performed in 189 women with threatened preterm labor.Cervical parameters of the ultrasonography were evaluated including cervical length,the presence of funneling,funnel length,funnel width and cervical indexs [(Funnel length +1)/Cervical length].Results: The prevalence of preterm delivery was 34.4%(65/189) in 189 women with threatened preterm labor.A significant association was indicated by logistic regression analysis between the occurrence of preterm delivery and ultrasonographic cervical parameters.But of all ultrasonographic parameters the cervical length were the best predictor of preterm delivery.Receiver operating characteristic curve(ROC) analyses showed that a cervical length of 25 mm was the optimal cut-off to predict the perterm delivery occurrence,the sensitivity,specificity,positive predictive value(PPV) and negative predictive value(NPV) were 67.7%,75.0%,58.7%,81.6%respectively.Conclusion: It is suggested that the transvaginal ultrasonographic measurement of the uterine cervix is an objective and accurate method in predicting preterm delivery for pregnant women with threatened preterm labor.

Key concepts: Medicine, Obstetrics, Preterm delivery, Cervix, Receiver operating characteristic, Gynecology, Logistic regression, Transvaginal ultrasonography

Related papers

Back to paper searchBrowse research topicsOriginal source
The value of transvaginal ultrasonographic examination of the uterine cervix in predicting preterm delivery for pregnant women with threatened preterm labor — Research Paper | ScholarLens