2015•Unpublished venueRequires access

A rat model of sciatica induced by autologous nucleus pulposus implant at outlet of lumbar intervertebral foramen

Han N. Le

Open publisher page 1 citations

Abstract

Objective To establish a new rat model for sciatica induced by autologous nucleus pulposus implant at outlet of lumbar intervertebral foramen. Methods A total of 54 male SD rats were randomly divided into a model group,a sham operation group and a blank group,18 rats in each one. 6 rats were selected from each group and observed on general behaviors and measured with 50% Paw Withdrawal Threshold( PWT) 1 day before surgery and 1,3,5,7,10 and 14 days after the surgery. Another 6 rats from each group were selected and tested with the expression of NOS and COX-2 in L5 dorsal root ganglion( DRG) after 3 days and 7 days of the surgery. Results No obvious motor dysfunction was seen in all rats. 50% PWT in model group after surgery was significantly lower than that before surgery and also significantly lower than that in the blank group and sham operation group( P 0. 01). The positive cells of NOS and COX-2 in L5 DRG in model group were significantly increased than that in the blank and sham operation group respectively after 3 days and 7 days of the surgery( P 0. 01). Conclusion This new rat model of sciatica induced by autologous nucleus pulposus implant at outlet of lumbar intervertebral foramen is convenient with less damage on joint structure,which can provide positive and stable pain. It could offer experiment basis for mechanism research regarding conservative therapies on radical irritation,especially for spinal manipulation.

About this research paper

What this paper is about

Objective To establish a new rat model for sciatica induced by autologous nucleus pulposus implant at outlet of lumbar intervertebral foramen. Methods A total of 54 male SD rats were randomly divided into a model group,a sham operation group and a blank group,18 rats in each one. 6 rats were selected from each group and observed on general behaviors and measured with 50% Paw Withdrawal Threshold( PWT) 1 day before surgery and 1,3,5,7,10 and 14 days after the surgery. Another 6 rats from each group were selected and tested with the expression of NOS and COX-2 in L5 dorsal root ganglion( DRG) after 3 days and 7 days of the surgery. Results No obvious motor dysfunction was seen in all rats. 50% PWT in model group after surgery was significantly lower than that before surgery and also significantly lower than that in the blank group and sham operation group( P 0. 01). The positive cells of NOS and COX-2 in L5 DRG in model group were significantly increased than that in the blank and sham operation group respectively after 3 days and 7 days of the surgery( P 0. 01). Conclusion This new rat model of sciatica induced by autologous nucleus pulposus implant at outlet of lumbar intervertebral foramen is convenient with less damage on joint structure,which can provide positive and stable pain. It could offer experiment basis for mechanism research regarding conservative therapies on radical irritation,especially for spinal manipulation.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To establish a new rat model for sciatica induced by autologous nucleus pulposus implant at outlet of lumbar intervertebral foramen. Methods A total of 54 male SD rats were randomly divided into a model group,a sham operation group and a blank group,18 rats in each one. 6 rats were selected from each group and observed on general behaviors and measured with 50% Paw Withdrawal Threshold( PWT) 1 day before surgery and 1,3,5,7,10 and 14 days after the surgery. Another 6 rats from each group were selected and tested with the expression of NOS and COX-2 in L5 dorsal root ganglion( DRG) after 3 days and 7 days of the surgery. Results No obvious motor dysfunction was seen in all rats. 50% PWT in model group after surgery was significantly lower than that before surgery and also significantly lower than that in the blank group and sham operation group( P 0. 01). The positive cells of NOS and COX-2 in L5 DRG in model group were significantly increased than that in the blank and sham operation group respectively after 3 days and 7 days of the surgery( P 0. 01). Conclusion This new rat model of sciatica induced by autologous nucleus pulposus implant at outlet of lumbar intervertebral foramen is convenient with less damage on joint structure,which can provide positive and stable pain. It could offer experiment basis for mechanism research regarding conservative therapies on radical irritation,especially for spinal manipulation.

Key concepts: Medicine, Sciatica, Intervertebral foramen, Intervertebral disc, Lumbar, Surgery, Rat model, Implant

Related papers

Back to paper searchBrowse research topicsOriginal source
A rat model of sciatica induced by autologous nucleus pulposus implant at outlet of lumbar intervertebral foramen — Research Paper | ScholarLens