Fe3+ had catalytic effect on the fading reaction of eriochrome blue black R oxidized by hydrogen peroxide in nitric acid medium.The concentration change of coloring agent was detected at 510 nm by flow injection automatic sampling technology and a new determination method of trace Fe3+ by flow injection catalytic kinetic spectrophotometry was established.The reaction medium,oxidizing agent,the volume ratio of nitric acid and hydrogen peroxide,the concentration of eriochrome blue black R,the reaction temperature and the pump speed were optimized.The effect of interference ions was investigated.The ions with serious interference such as copper and lead were masked by sodium thiosulfate to eliminate the interference.The linear range of this method was 0.08-0.68 μg/mL,and the detection limit was 9.77×10-4 μg/mL.The relative standard deviation(RSD,n=11) of 0.2 μg/mL Fe3+ was 0.4 %.The analytical speed was 48.6 times/h.The proposed method could be applied to the determination of trace iron (Ⅲ) in environmental water samples such as rain water,tap water and river water.

About this research paper

What this paper is about

Fe3+ had catalytic effect on the fading reaction of eriochrome blue black R oxidized by hydrogen peroxide in nitric acid medium.The concentration change of coloring agent was detected at 510 nm by flow injection automatic sampling technology and a new determination method of trace Fe3+ by flow injection catalytic kinetic spectrophotometry was established.The reaction medium,oxidizing agent,the volume ratio of nitric acid and hydrogen peroxide,the concentration of eriochrome blue black R,the reaction temperature and the pump speed were optimized.The effect of interference ions was investigated.The ions with serious interference such as copper and lead were masked by sodium thiosulfate to eliminate the interference.The linear range of this method was 0.08-0.68 μg/mL,and the detection limit was 9.77×10-4 μg/mL.The relative standard deviation(RSD,n=11) of 0.2 μg/mL Fe3+ was 0.4 %.The analytical speed was 48.6 times/h.The proposed method could be applied to the determination of trace iron (Ⅲ) in environmental water samples such as rain water,tap water and river water.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Fe3+ had catalytic effect on the fading reaction of eriochrome blue black R oxidized by hydrogen peroxide in nitric acid medium.The concentration change of coloring agent was detected at 510 nm by flow injection automatic sampling technology and a new determination method of trace Fe3+ by flow injection catalytic kinetic spectrophotometry was established.The reaction medium,oxidizing agent,the volume ratio of nitric acid and hydrogen peroxide,the concentration of eriochrome blue black R,the reaction temperature and the pump speed were optimized.The effect of interference ions was investigated.The ions with serious interference such as copper and lead were masked by sodium thiosulfate to eliminate the interference.The linear range of this method was 0.08-0.68 μg/mL,and the detection limit was 9.77×10-4 μg/mL.The relative standard deviation(RSD,n=11) of 0.2 μg/mL Fe3+ was 0.4 %.The analytical speed was 48.6 times/h.The proposed method could be applied to the determination of trace iron (Ⅲ) in environmental water samples such as rain water,tap water and river water.

Key concepts: Hydrogen peroxide, Chemistry, Detection limit, Spectrophotometry, Nitric acid, Oxidizing agent, Catalysis, Tap water

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of trace iron in environmental water samples by flow injection catalytic spectrophotometry — Research Paper | ScholarLens