Determination of Trace Cobalt in Water by Reversed Flow Injection Spectrophotometry
Ling Su, Heng Xie
Abstract
Ling Su, Heng Xie
Abstract
A method for determination of cobalt in water by flow injection spectrophotometry based on the catalytic effects of cobalt on the oxidation reaction of arsenazo III by potassium bichromate in HAc-NaAc buffer solution of pH 4.6 was established. The relationship of the reduced absorbency to the concentration of cobalt was good linearity and the maximum absorption peak located at 550 nm. The affecting factors on the strength of absorption including acidity, dosage, temperature, coexisting ions and so on, and the optimal conditions of the reaction in the system were investigated. Calibration graphs were linear for ranges of 0 to 20 μg/mL and a detection limit of 0.3 μg/mL cobalt was achieved. The proposed method was successfully applied to the analyses of industrial waste water samples, with relative standard deviation of less than 1.5% and the recoveries are 95.1% to 96.8%for the determination of cobalt.
OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A method for determination of cobalt in water by flow injection spectrophotometry based on the catalytic effects of cobalt on the oxidation reaction of arsenazo III by potassium bichromate in HAc-NaAc buffer solution of pH 4.6 was established. The relationship of the reduced absorbency to the concentration of cobalt was good linearity and the maximum absorption peak located at 550 nm. The affecting factors on the strength of absorption including acidity, dosage, temperature, coexisting ions and so on, and the optimal conditions of the reaction in the system were investigated. Calibration graphs were linear for ranges of 0 to 20 μg/mL and a detection limit of 0.3 μg/mL cobalt was achieved. The proposed method was successfully applied to the analyses of industrial waste water samples, with relative standard deviation of less than 1.5% and the recoveries are 95.1% to 96.8%for the determination of cobalt.
Key concepts: Cobalt, Spectrophotometry, Detection limit, Chemistry, Chromium, Flow injection analysis, Analytical Chemistry (journal), Atomic absorption spectroscopy