2002Analytical LaboratoryRequires access

Determination of Pt and Pd in spent Al_2O_3 catalyst by ICP-AES

Liu Ying

Open publisher page 0 citations

Abstract

A new method for the determination of Pt and Pd in the spent Al 2O 3 catalyst by ICP AES was established. The operation parameters of ICP AES, the dissolution of samples, the effects of inorganic acid, the influence of matrix and coexisting elements were tested. The results indicated that the platinum and palladium could be determined directly with calibration curve method by ICP AES without matrix matching in 5% HCl medium. The detection limits were 0.1 μg/mL for Pt, and 0.045 μg/mL for Pd. The recovery was 95.2%~105.5% for Pt, and 95.3%~100.6% for Pd. The RSD were 9%. The method was applied to determine Pt and Pd in spent Al 2O 3 catalyst with satisfactory results.

About this research paper

What this paper is about

A new method for the determination of Pt and Pd in the spent Al 2O 3 catalyst by ICP AES was established. The operation parameters of ICP AES, the dissolution of samples, the effects of inorganic acid, the influence of matrix and coexisting elements were tested. The results indicated that the platinum and palladium could be determined directly with calibration curve method by ICP AES without matrix matching in 5% HCl medium. The detection limits were 0.1 μg/mL for Pt, and 0.045 μg/mL for Pd. The recovery was 95.2%~105.5% for Pt, and 95.3%~100.6% for Pd. The RSD were 9%. The method was applied to determine Pt and Pd in spent Al 2O 3 catalyst with satisfactory results.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new method for the determination of Pt and Pd in the spent Al 2O 3 catalyst by ICP AES was established. The operation parameters of ICP AES, the dissolution of samples, the effects of inorganic acid, the influence of matrix and coexisting elements were tested. The results indicated that the platinum and palladium could be determined directly with calibration curve method by ICP AES without matrix matching in 5% HCl medium. The detection limits were 0.1 μg/mL for Pt, and 0.045 μg/mL for Pd. The recovery was 95.2%~105.5% for Pt, and 95.3%~100.6% for Pd. The RSD were 9%. The method was applied to determine Pt and Pd in spent Al 2O 3 catalyst with satisfactory results.

Key concepts: Chemistry, Inductively coupled plasma atomic emission spectroscopy, Palladium, Catalysis, Platinum, Calibration curve, Dissolution, Matrix (chemical analysis)

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Pt and Pd in spent Al_2O_3 catalyst by ICP-AES — Research Paper | ScholarLens