Clinical application of color Doppler ultrasound and non-stress test in diagnosis of fetal distress
Yun-ru Wang
Abstract
Yun-ru Wang
Abstract
Objective To investigate the clinical value of color Doppler ultrasound and non-stress test(NST)in diagnosis of fetal distress.Methods A total of 80 fetuses between 37-42 weeks of gestation were divided into 2 groups--distress group and normal control group(n = 40 for each)and examined with color Doppler ultrasound and NST.Results The ratio of peak systolic to end diastolic flow velocity(S/D),resistance index(RI)and pulsatility index(PI)of fetal middle cerebral artery(MCA)had significant differences between fetal distress group and normal group.The sensitivity,specificity,the positive and negative predictive value of normal and distress group were 92.5 %,95.0 %,94.5 % and 92.7 % in fetal hypoxia by color Doppler and 75.0 %,62.5 %,66.7 %,71.4 % by NST respectively,the detection rate of fetal distress by S/D ratio was significantly higher than that in NST.Conclusion It is demonstrated that hemodynamic index(S/D)is superior to NST in diagnosis of fetal distress by χ2 test of paired comparison.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To investigate the clinical value of color Doppler ultrasound and non-stress test(NST)in diagnosis of fetal distress.Methods A total of 80 fetuses between 37-42 weeks of gestation were divided into 2 groups--distress group and normal control group(n = 40 for each)and examined with color Doppler ultrasound and NST.Results The ratio of peak systolic to end diastolic flow velocity(S/D),resistance index(RI)and pulsatility index(PI)of fetal middle cerebral artery(MCA)had significant differences between fetal distress group and normal group.The sensitivity,specificity,the positive and negative predictive value of normal and distress group were 92.5 %,95.0 %,94.5 % and 92.7 % in fetal hypoxia by color Doppler and 75.0 %,62.5 %,66.7 %,71.4 % by NST respectively,the detection rate of fetal distress by S/D ratio was significantly higher than that in NST.Conclusion It is demonstrated that hemodynamic index(S/D)is superior to NST in diagnosis of fetal distress by χ2 test of paired comparison.
Key concepts: Medicine, Fetal distress, Fetus, Gestation, Diastole, Ultrasound, Internal medicine, Distress