2006•Journal of Jianghan UniversityRequires access

Flow Injection On Line Solid Phase Extraction Pre-concentration System for Pb Determination by FAAS

Haiou Qiu

Open publisher page 0 citations

Abstract

A new method of flow injection on-line solid phase extraction pre-concentration sys-tem for Pb determination by flame atomic absorption spectrometry(FAAS) was adopted.Trace amounts of lead in the water sample was chelated by xylenol orange and exchanged in the strong al-kalescent negative ion exchange resin column,and then eluted by nitric acid.The lead content was determined by flow injection-flame atomic absorption spectrometry.The working parameters and chemical conditions were discussed and optimized.Interferential experiments with familiar ions in natural water were done.The detection limit was 11.1 ng/mL and the relative standard deviation of this method was 1.80%.The recovery was 96.2% ~ 103.8%.

About this research paper

What this paper is about

A new method of flow injection on-line solid phase extraction pre-concentration sys-tem for Pb determination by flame atomic absorption spectrometry(FAAS) was adopted.Trace amounts of lead in the water sample was chelated by xylenol orange and exchanged in the strong al-kalescent negative ion exchange resin column,and then eluted by nitric acid.The lead content was determined by flow injection-flame atomic absorption spectrometry.The working parameters and chemical conditions were discussed and optimized.Interferential experiments with familiar ions in natural water were done.The detection limit was 11.1 ng/mL and the relative standard deviation of this method was 1.80%.The recovery was 96.2% ~ 103.8%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new method of flow injection on-line solid phase extraction pre-concentration sys-tem for Pb determination by flame atomic absorption spectrometry(FAAS) was adopted.Trace amounts of lead in the water sample was chelated by xylenol orange and exchanged in the strong al-kalescent negative ion exchange resin column,and then eluted by nitric acid.The lead content was determined by flow injection-flame atomic absorption spectrometry.The working parameters and chemical conditions were discussed and optimized.Interferential experiments with familiar ions in natural water were done.The detection limit was 11.1 ng/mL and the relative standard deviation of this method was 1.80%.The recovery was 96.2% ~ 103.8%.

Key concepts: Solid phase extraction, Detection limit, Elution, Nitric acid, Chemistry, Analytical Chemistry (journal), Extraction (chemistry), Chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Flow Injection On Line Solid Phase Extraction Pre-concentration System for Pb Determination by FAAS — Research Paper | ScholarLens