2012•Unpublished venueRequires access

FI on-Line Adsorption and Preconcentration Coupled with FAAS for the Determination of Trace Cu in Rice

Sachin Mittal

Open publisher page 0 citations

Abstract

A flow injection knotted reactor preconcentration system coupled to flame atomic absorption spectrometry(FAAS)was developed for the determination of trace Cu in rice.With 60 s(sample throughput of 37/h)of sampling at a flow rate of 6.0 mL/min,an EF of 13.5(higher than 4.5 which achieved by Conventional elution method)and a detection limit of 5.4 μg/L were obtained.The precision(RSD,n=11)was 2.3% at the 200 μg/L level.When 0.01 % triethannolamine was used as masking reagent,the recovery rate of Cu in rice was from 96.4%~97.8%.

About this research paper

What this paper is about

A flow injection knotted reactor preconcentration system coupled to flame atomic absorption spectrometry(FAAS)was developed for the determination of trace Cu in rice.With 60 s(sample throughput of 37/h)of sampling at a flow rate of 6.0 mL/min,an EF of 13.5(higher than 4.5 which achieved by Conventional elution method)and a detection limit of 5.4 μg/L were obtained.The precision(RSD,n=11)was 2.3% at the 200 μg/L level.When 0.01 % triethannolamine was used as masking reagent,the recovery rate of Cu in rice was from 96.4%~97.8%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A flow injection knotted reactor preconcentration system coupled to flame atomic absorption spectrometry(FAAS)was developed for the determination of trace Cu in rice.With 60 s(sample throughput of 37/h)of sampling at a flow rate of 6.0 mL/min,an EF of 13.5(higher than 4.5 which achieved by Conventional elution method)and a detection limit of 5.4 μg/L were obtained.The precision(RSD,n=11)was 2.3% at the 200 μg/L level.When 0.01 % triethannolamine was used as masking reagent,the recovery rate of Cu in rice was from 96.4%~97.8%.

Key concepts: Chemistry, Detection limit, Elution, Analytical Chemistry (journal), Reagent, Chromatography, Volumetric flow rate, Recovery rate

Related papers

Back to paper searchBrowse research topicsOriginal source
FI on-Line Adsorption and Preconcentration Coupled with FAAS for the Determination of Trace Cu in Rice — Research Paper | ScholarLens