2007Modern Medicine HealthRequires access

Bias analysis on the results of bilirubin among different analysis systems

Xianzhang Huang

Open publisher page 0 citations

Abstract

Objective:To study the comparability on the results of bilirubin among different analysis systems.Methods:With the analysis system 1 with the Hitachi7170 A biochemical analyzers,Roche reagent and program,Roche c-fas calibration as a target system and detecting systems 2 and 3 as comment system,the total and direct bilirubin were analysed in 45 patient fresh sera and 2 levels of Randox controls.Results:Analysis of variance showed that the results of total bilirubin(TBIL)and direct bilirubin(DBIL) from RANDOX controls and patient sera had significant difference between system 1 and system2 or 3,and also the correlation coefficient was all above 0.975.The result of TBIL in system 2 was partly exceeded T±10%,the other results were all exceeded T±10%.Conclusion:The results of TBIL and DBIL in three analysis systems were incomparability.

About this research paper

What this paper is about

Objective:To study the comparability on the results of bilirubin among different analysis systems.Methods:With the analysis system 1 with the Hitachi7170 A biochemical analyzers,Roche reagent and program,Roche c-fas calibration as a target system and detecting systems 2 and 3 as comment system,the total and direct bilirubin were analysed in 45 patient fresh sera and 2 levels of Randox controls.Results:Analysis of variance showed that the results of total bilirubin(TBIL)and direct bilirubin(DBIL) from RANDOX controls and patient sera had significant difference between system 1 and system2 or 3,and also the correlation coefficient was all above 0.975.The result of TBIL in system 2 was partly exceeded T±10%,the other results were all exceeded T±10%.Conclusion:The results of TBIL and DBIL in three analysis systems were incomparability.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To study the comparability on the results of bilirubin among different analysis systems.Methods:With the analysis system 1 with the Hitachi7170 A biochemical analyzers,Roche reagent and program,Roche c-fas calibration as a target system and detecting systems 2 and 3 as comment system,the total and direct bilirubin were analysed in 45 patient fresh sera and 2 levels of Randox controls.Results:Analysis of variance showed that the results of total bilirubin(TBIL)and direct bilirubin(DBIL) from RANDOX controls and patient sera had significant difference between system 1 and system2 or 3,and also the correlation coefficient was all above 0.975.The result of TBIL in system 2 was partly exceeded T±10%,the other results were all exceeded T±10%.Conclusion:The results of TBIL and DBIL in three analysis systems were incomparability.

Key concepts: Medicine, Bilirubin, Direct bilirubin, Spectrum analyzer, Analysis of variance, Gastroenterology, Internal medicine, Biochemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Bias analysis on the results of bilirubin among different analysis systems — Research Paper | ScholarLens