2009Journal of Chongqing University of Arts and SciencesRequires access

Catalytic Kinetic Spectrometric determination of trace Cr(VI) with Cr(VI)-Crystal Violet-Hydrogen Peroxide system

Jiahong He

Open publisher page 0 citations

Abstract

It was based on the chromium(Ⅵ) which could catalyze the redox reaction between H2O2 and Crystal Violet in H2SO4 aqueous solution medium at 75 ℃.The absorbance difference(△A) between catalytic reaction and non-catalytic reaction was linear with the concentration of chromium(Ⅵ) in a certain range.On optimum conditions,calibration curve was linear in the range of 0~96 μg·mL-1,with the detection limit as low as 6.91 μg·mL-1(regression coefficient was 0.998 5).The regression equation was △A = 0.0033 + 0.1401C(μg/25mL).The method was simple and selective.It has been applied satisfactorily to the determination of chromium(Ⅵ) in wastewater samples.

About this research paper

What this paper is about

It was based on the chromium(Ⅵ) which could catalyze the redox reaction between H2O2 and Crystal Violet in H2SO4 aqueous solution medium at 75 ℃.The absorbance difference(△A) between catalytic reaction and non-catalytic reaction was linear with the concentration of chromium(Ⅵ) in a certain range.On optimum conditions,calibration curve was linear in the range of 0~96 μg·mL-1,with the detection limit as low as 6.91 μg·mL-1(regression coefficient was 0.998 5).The regression equation was △A = 0.0033 + 0.1401C(μg/25mL).The method was simple and selective.It has been applied satisfactorily to the determination of chromium(Ⅵ) in wastewater samples.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

It was based on the chromium(Ⅵ) which could catalyze the redox reaction between H2O2 and Crystal Violet in H2SO4 aqueous solution medium at 75 ℃.The absorbance difference(△A) between catalytic reaction and non-catalytic reaction was linear with the concentration of chromium(Ⅵ) in a certain range.On optimum conditions,calibration curve was linear in the range of 0~96 μg·mL-1,with the detection limit as low as 6.91 μg·mL-1(regression coefficient was 0.998 5).The regression equation was △A = 0.0033 + 0.1401C(μg/25mL).The method was simple and selective.It has been applied satisfactorily to the determination of chromium(Ⅵ) in wastewater samples.

Key concepts: Crystal violet, Chromium, Hydrogen peroxide, Catalysis, Chemistry, Absorbance, Calibration curve, Detection limit

Related papers

Back to paper searchBrowse research topicsOriginal source
Catalytic Kinetic Spectrometric determination of trace Cr(VI) with Cr(VI)-Crystal Violet-Hydrogen Peroxide system — Research Paper | ScholarLens