Simultaneous Determination of Benzophenone-2 and Benzophenone-3 in Cosmetics by HPLC Method
Che Ma
Abstract
Che Ma
Abstract
Objective To establish a high performance liquid chromatography(HPLC) method for the determination of benzophenone-2 and benzophenone-3 in cosmetics.Methods The samples were treated by ultrasonic in acetonitrile-water before detected by HPLC-UV.The analytical column was Phenomenex GEMINI C18 110A(250 mm×4.6 mm,5 μm).The mobile phase was acetonitrile-water.The flow rate was 1.0 ml/min.The detection wave length was 335 nm and the column temperature was 30 ℃.Results The linear calibration curves were obtained over the range of 1-150 μg/ml for both benzophenone-2 and benzophenone-3,the correlation coefficients were more than 0.999,the detection limits were 0.15 μg/ml,the limits of quantification were 1 μg/ml.The recoveries of the two compounds were between 90% and 100%,and the relative standard deviations were less than 2.0%.Conclusion This method was simple and accurate for the simultaneous determination of the content of benzophenone-2 and benzophenone-3 in cosmetics which do not contain wax.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To establish a high performance liquid chromatography(HPLC) method for the determination of benzophenone-2 and benzophenone-3 in cosmetics.Methods The samples were treated by ultrasonic in acetonitrile-water before detected by HPLC-UV.The analytical column was Phenomenex GEMINI C18 110A(250 mm×4.6 mm,5 μm).The mobile phase was acetonitrile-water.The flow rate was 1.0 ml/min.The detection wave length was 335 nm and the column temperature was 30 ℃.Results The linear calibration curves were obtained over the range of 1-150 μg/ml for both benzophenone-2 and benzophenone-3,the correlation coefficients were more than 0.999,the detection limits were 0.15 μg/ml,the limits of quantification were 1 μg/ml.The recoveries of the two compounds were between 90% and 100%,and the relative standard deviations were less than 2.0%.Conclusion This method was simple and accurate for the simultaneous determination of the content of benzophenone-2 and benzophenone-3 in cosmetics which do not contain wax.
Key concepts: Benzophenone, Chromatography, High-performance liquid chromatography, Chemistry, Acetonitrile, Cosmetics, Detection limit, Calibration curve